System Configuration Options - Sea Breeze SMZ18H46ZOGX Installation Manual

High efficiency series mini-split dual / triple / quad zone
Table of Contents

Advertisement

System Configuration Options

Dual Zone
SMZ18H46ZOGX (2 indoor units)
Note: Do not mismatch or connect to an outdoor unit other than the designed matched system.
ONE INDOOR UNIT
9K
12K
Triple Zone
SMZ24H46ZOGX (2 to 3 indoor units)
Note: 1. Do not mismatch or connect to an outdoor unit other than the designed matched system.
2. This system must be used with a minimum of two indoor units (evaporators).
2 INDOOR UNITS
9K + 9K
9K + 12K
9K + 18K
12K + 12K
12K + 18K
Quad Zone
SMZ30H46ZOGX (2 to 4 indoor units)
Note: 1. Do not mismatch or connect to an outdoor unit other than the designed matched system.
2. This system must be used with a minimum of two indoor units (evaporators).
2 INDOOR UNITS
9K + 9K / 9K + 12K
9K + 18K / 12K + 12K
12K + 18K / 18K + 18K
The system matches below are not recommended if all indoor units may require simultaneous continuous duty at full efficiency.
18K + 18K
Indoor Models Available:
Indoor Unit Type
Wall-mounted Indoor Unit A
Wall-mounted Indoor Unit B
Console Indoor Unit
Cassette Indoor Unit
Floor / Ceiling Indoor Unit
Ducted Indoor Unit
950-0195revJ
TWO INDOOR UNITS
9K + 9K
9K + 12k
3 INDOOR UNITS
9K + 9K + 9K / 9K + 9K + 12K
9K + 9K + 18K / 9K + 12K + 12K
12K + 12K + 12K
9K + 12K + 18K
12K + 12K + 18K
Catalog Number
SHE9H4ZIGX
SHE12H4ZIGX
SHE18H4ZIGX
SHE9H4ZIGB
SHE12H4ZIGB
SHE18H4ZIGB
SMZC9H4ZIGX
SMZC12H4ZIGX
SMZC18H4ZIGX
SMZCA12H4ZIGX
SMZCA18H4ZIGX
SMZFC9H4ZIGX
SMZFC12H4ZIGX
SMZFC18H4ZIGX
SMZD9H4ZIGX
SMZD12H4ZIGX
SMZD18H4ZIGX
3 INDOOR UNITS
9K + 9K + 9K
9K + 9K + 12K
9K + 12K + 12K
9K + 9K + 12K + 12K
Outline
For the detail information
about connecting, please
refer to the specific manual
included with each indoor
unit.
- 6 -
4 INDOOR UNITS
9K + 9K + 9K + 9K
9K + 9K + 9K + 12K
Remark
December 3, 2015

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents