OUTDOOR UNIT (CONDENSER) INSTALLATION

The location must allow easy servicing and provide good air circulation as shown in the illustration below:
OUTDOOR
(CONDENSER)
UNIT
Shaded area
must be clear
Figure 8 (Top View)
Mounting the Outdoor (condenser) Unit
Follow the clearance guidelines in the
diagram above. Clearance distances
are minimums. Minimum clearance
above unit is 12" to allow for servicing.
For Heat Pump units, install drain plug
as in Figure 9 (included). Drain hose
not included.
Do not mount this unit close to
combustibles or heat sources.
Although this unit is fairly quiet when
Figure 9
in operation, do not mount this unit
where noise issues could be a problem.
Mount unit on an equipment pad or solid surface, install drain plug and tube as necessary. If wall mounting is
necessary a wall mount bracket may be purchased (BR-440L) for this purpose. Follow mounting instructions
for bracket to ensure safe installation.
Anchor bolts of the proper size and type (Installer provided) must be used.
For best results mount this unit as close as possible to the evaporators. Check maximum line length
specifications before mounting.
MAXIMUM LINE LENGTH MUST NOT BE EXCEEDED! (See pages 16-19)