  • Page 1 Operations Manual Wave Motion Shaker V1 12/21/17...
  • Page 2 This manual covers the model shown below Voltage Description NA Model EU Model Wave Motion Shaker US plug 88861027 100~240V Wave Motion Shaker Intl plug 88861028 15524070 100~240V...
  • Page 3 Caution all internal adjustments and maintenance must be performed by qualified service personnel. Material in this manual is for information purposes only. Fisher Scientific is committed to a continuing program of product development and improvement, and reserves the right to change information, such as specifications, appearance, and dimensions, described in this document without notice.
  • Page 4: Table Of Contents

    Contents Section 1 Inspection and Installation Packing List Connections Structure Diagram Section Overview Specifications Environmental Conditions Safety Instructions Relationships between Speed and Load Section 3 Operation Control Panel Installation Settings Tilt Angle Adjustment Replace The Rubber Tube Section 4 Safety Tips and Maintenance Section 5 Troubleshooting Section 6 Optional Accessories/Spare Parts Section 7 Warranty...
  • Page 5: Section 1 Inspection And Installation

    Section 1 Inspection and Installation 1. Inspect package and contents upon receipt of the instruments. all the components before discarding the packing. If there are If the package is severely damaged or if there are any missing any missing or damaged pieces, please contact the pieces, please contact the manufacturer immediately.
  • Page 6: Section 2 Overview

    Section 2 Overview 2.1 Specifications 2.2 Environmental Conditions Category Number Application Environmental Conditions: indoor use Description Temperature NA Cat.No. NA/EU Cat.No. 5 to 40℃(41 to 104℉) ±10% of the nominal voltage Voltage Fluctuation 88861028 88861027 /15524070 Wave Motion Shaker ≤2,000 m US plug Altitude Intl plug...
  • Page 7: Relationships Between Speed And Load

    Position of Loads Place the loads in the recommended positions below: Please use rubber strips to fasten containers onto 1. Place load at the center of the tray the tray when using this instrument to avoid 2. Place loads symmetrically around the center of the tray accidents.
  • Page 8: Section 3 Operation

    Section 3 Operation This chapter covers the control panel and its operation. 3.1 Control Panel ③ ④ ② TIME ① ⑥ ⑤ The front panel of the Wave Motion Shaker contains all the controls needed to operate the unit. window. When the number shown on the display window starts 1.
  • Page 9: Tilt Angle Adjustment

    Note: Warning: 1.The instrument should be unloaded and stopped at the To ensure shaking operation smooth and steady, it may take specified position when adjusting the angle. It is not 1minute for the microprocessor control system to allowed to adjust the angle at other positions. accelerate the tray to the set speed.
  • Page 10: Replace The Rubber Tube

    3.5 Replace The Rubber Tube 3. Place the new small rubber tube in place and tighten it After prolonged use, the small rubber tubes may be damaged. Please follow the steps below to replace these just with hand or tighten the screw in the small rubber small rubber tubes.
  • Page 11: Section 4 Safety Tips And Maintenance

    Section 4 Safety Tips and Maintenance Safety Tips Warning: Avoid dripping detergent or water into the inside of the instrument during cleaning. 1. Use independent power supply. 2. Check if the local power supply voltage is suitable for use. Clean Spill 3.
  • Page 12: Section 5 Troubleshooting

    Adjust the weight and position of load, Over-weighted or unbalanced load decrease rotation speed Push the knob to “Adjust Angle” Push the knob to “Run” position position No shaking of the tray Contact Fisher Scientific Electrical malfunction Mechanical malfunction Contact Fisher Scientific Platform shaking Place Instrument...
  • Page 13: Section 6 Optional Accessories/Spare Parts

    Section 6 Optional Accessories/Spare Parts EU Cat. No. Description Max. Qty Figure NA Cat. No. Dimensions Dimpled Rubber Mat 88861198 15594130 298×258mm (Spare Part) Rubber Strips 180×7mm(6pcs/pack) 88861178 15594120 (Spare Part) General Power Adaptor 88861154 15554120 AC 100 240V, 50/60HZ (Spare Part) Power Cable US Plug...
  • Page 14: Section 7 Warranty

    When used in laboratory conditions and according to these operation instructions and maintenance, this product is warranted for 24 months against defective materials or workmanship. The 24 month warranty period begins from the delivery date of this product. For product quality or performance issues, contact Fisher Scientific Customer Service.
  • Page 15 North America United States Canada 1-800-766-7000 1-800-234-7437 fishersci.com fishersci.ca Europe Austria: Netherlands: +43(0)800-20 88 40 +31(0)20 4887 70 00 at.fishersci.com nl.fishersci.com Belgium: Norway: +32(0)56 260 260 +47 22 95 59 59 be.fishersci.com fishersci.no Denmark: Portugal: +45 70 27 99 20 +351 21 425 33 50 fishersci.dk pt.fishersci.com...