Fisher Scientific Fisherbrand Isotemp RT 11676259 Operation Manual
Fisher Scientific Fisherbrand Isotemp RT 11676259 Operation Manual

Fisher Scientific Fisherbrand Isotemp RT 11676259 Operation Manual

Hotplate stirrer

Advertisement

Quick Links

Isotemp RT
Operation Manual
Hotplate Stirrer
9240-11-012 V01 12/01/17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fisherbrand Isotemp RT 11676259 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fisher Scientific Fisherbrand Isotemp RT 11676259

  • Page 1 Isotemp RT Operation Manual Hotplate Stirrer 9240-11-012 V01 12/01/17...
  • Page 2 This manual cover the model is shown below NA Model EU Model Voltage Description 11676259 15316607 230V-EU, UK, ANZ/CN Isotemp RT HPS 230V 11676260 120V-US Isotemp RT HPS120V...
  • Page 3 Caution All internal adjustments and maintenance must be performed by qualified service personnel. Material in this manual is for information purposes only. Fisher Scientific is committed to a continuing program of product development and improvement, and reserves the right to change information, such as specifications, appearance, and dimensions, described in this document without notice.
  • Page 4 Preface This manual contains important safety and operation information. You must carefully read, understand, and follow all the instructions in this manual prior to operating this instrument. Keep this manual in a safe place nearby for reference and make it easily available to all users. 1) This manual highlights DANGER/WARNING/CAUTION/NOTICE alerts to prevent injury or property damage and also to achieve optimum performance of your instrument.
  • Page 5: Table Of Contents

    Table of Contents Section 1 Warning and Cautions ------------------------------------------- Section 2 General Description ---------------------------------------------- Features --------------------------------------------------------------- Ease of Use ------------------------------------------------------------ Durability --------------------------------------------------------------- Construction ----------------------------------------------------------- Section 3 Unpacking and Installation -------------------------------------- Installation Environment ---------------------------------------------- Location Conditions -------------------------------------------------- Connecting to Main Power Supply ---------------------------------- Section 4 Control Panel ----------------------------------------------------- Heater Operation ------------------------------------------------------...
  • Page 6: Warning And Cautions

    Warnings and Cautions Section 1 Ignoring the following warnings could cause serious injuries or even fatal accidents. Always wear proper protective gear (such as goggles, gloves, masks or an apron) when using this instrument. Never install or use this instrument in explosive atmospheres. Never use the instrument to heat flammable liquids.
  • Page 7 Section 1 Warnings and Cautions Ignoring the following cautions could cause injuries or property damages. Do not touch the top plate or any object near it even when the heater is turned off. You may get burned due to residual heat. After using this equipment, make sure to turn off the main power switch and also to disconnect the power cord from the power outlet for the safety of other users.
  • Page 8: General Description

    General Description Section 2 Congratulations of your purchase of a Fisher Scientific Isotemp RT Hotplate Stirrer which is specially designed to provide maximum benefit for your investment with respect to performance, safety, ease of use, and durability at end of paragraph.
  • Page 9 General Description • Big Stirring Capacity Features(continued) The BLDC motor and the special magnet also provide big stirring capacity (up to 20 liter in case of water). • Constant Stirring Speed The feedback control design of this instrument allows you to have constant stirring speed even when the viscosity of the media changes during operation.
  • Page 10: Ease Of Use

    Section 2 General Description Features(continued) Figure 2-1. Heating Bath • Transparent Shield (optional) A transparent shield is also available to allow you to monitor your operations more safely by shielding you against decoupled stir bars or liquid splashes. • With two separate knobs for heat and speed control, you can set Ease of Use heating level and/or stirring speed fast and with ease.
  • Page 11: Construction

    Section 2 General Description Construction Figure 2-2. Front Components (1) Ceramic-coated Top Plate (2) Heat Sink (3) Heater Knob (4) Control Panel (refer to Control Panel) (5) Stirrer Knob (6) Threaded Holes for Support Rods (7) Main Power Switch Figure 2-3. Back Components (8) Power Socket (9) Heating Bath (Optional) (10) Support Rod (Optional)
  • Page 12: Unpacking And Installation

    If such damage is found, notify the carrier immediately. After unpacking, check to ensure that all the following parts and accessories are included in the package. If not, contact Fisher Scientific immediately. Item...
  • Page 13: Location Conditions

    Section 3 Unpacking and Installation Location Conditions • Never install or use this equipment in explosive atmospheres. • Never install or use this equipment with or near to hazardous or flammable substances. • Never operate this instrument under water, where water can get into the instrument, or in an excessively wet environment.
  • Page 14: Control Panel

    Control Panel Section 4 This Fisher Scientific hotplate stirrer is equipped with a user-friendly control panel which has two big knobs, three operational status LEDs, and a hot top warning indicator. Figure 4-1. Control Panel A. Hot Top Warning Indicator B.
  • Page 15: Heater Operation

    Section 4 Control Panel Heater Operation • To avoid fires or injuries, make sure that the temperature is kept safely below the flash point of the media to be heated. • Be sure to wear proper protective gear (such as goggles, gloves, masks or an apron) when using this instrument.
  • Page 16: Stirrer Operation

    Section 4 Control Panel Heater Operation (2) If you want to turn off the heater, turn the heater knob counter- clockwise until you hear the ‘click’ sound. (continued) Stirrer Operation • Never place a cold glass vessel onto a hot top plate. •...
  • Page 17: Maintenance

    Maintenance Section 5 Inspection Interval Item Daily Weekly ● Connection status of power cord or plug. ● Damages in power cord or plug. ● Damages or cleanliness of top plate. ● Cleanliness of main body and accessories. Damages in switches, buttons, LED’s, dial ●...
  • Page 18: Relocation

    Section 5 Maintenance Cleaning Product Always make sure to keep top plate, main body, and accessories clean. (continued) Dirt and other foreign substances can cause fire or electric shock. Before attempting cleaning, - Disconnect the power cord from the power outlet and ensure that the instrument is cool enough, - Wipe with a soft dry cloth first to remove any foreign matter and, if not enough,...
  • Page 19: Trouble Shooting

    Damages in power cords, Replace the damaged part with a proper one power outlets or plugs. Internal circuit failure Contact Fisher Scientific for service. Disconnect all the appliances connected to the Electrical overload breaker first and reconnect them one by one to Repetitive tripping of the find the reason for the overload.
  • Page 20 Then, turn on the main blackout. power switch. Internal circuit failure. Contact Fisher Scientific for service. Too low setting of the Turn the heater knob clockwise to increase the No or too slow heating level.
  • Page 21: Accessories

    Accessories Section 7 NA Model EU Model Description 11676269 15366607 FS Heating Bath 11676270 15376607 FS Transparent Shield (PC) 11676271 15386607 FS Support Rod (12Ø support, 400mm, M10) 11676276 15346617 FS Clamp Holder (PP body, Ø12mm) 11676277 15356617 FS 3 Prong Clamp ( 60mm grip) Support Rod Assembly Hand-screw the support rod(s) into the threaded hole(s) as shown in the diagram.
  • Page 22 Section 7 Accessories...
  • Page 23: Transparent Shield & Heating Bath Assembly

    Transparent Shield & When necessary, the transparent shield and/or the heating bath can be Heating Bath Assembly easily assembled as shown below:...
  • Page 24: Technical Specifications

    Maximum load (kg/lbs) 25 / 55.1 ※ Unless otherwise specified, the above-mentioned data represent values at 25° C and 60% relative humidity. ※ Fisher Scientific reserves the right to make changes in design and specification without prior notice. Section 8...
  • Page 25: Disposing Of The Unit

    Technical Specifications Disposing of the Unit Disposing of your instrument must be done in an environmentally responsible way if it has been potentially exposed to bio-agents or radioactive samples. Failure to follow stringent requirements for instrument disposal may lead to actions against you and your organization.
  • Page 26: Warranty Information

    When used in laboratory conditions and according to these operation instructions and maintenance, this product is warranted for 24 months against defective materials or workmanship. The 24 month warranty period begins from the delivery date of this product. For product quality or performance issues, contact Fisher Scientific Customer Service.
  • Page 29 +41(0)56 618 41 11 it.fishersci.com ch.fishersci.com Finland +358(0)9 8027 6280 +44(1)1509 555 500 fishersci.fi fisher.co.uk France: +33(0)388 67 14 14 fishersci.fr Find out more at fishersci.com © 2017 Thermo Fisher Scientific Inc. All rights reserved. Trademarks used are owned as indicated at fishersci.com/trademarks.