Page 1
Operations Manual Multi Function Rotator V1 12/05/17...
Page 2
This manual covers the model shown below Voltage Description NA Model EU Model Multi Function Rotator US plug 88861047 100~240V Multi Function Rotator Intl plug 88861048 15514080 100~240V...
Page 3
Caution all internal adjustments and maintenance must be performed by qualified service personnel. Material in this manual is for information purposes only. Fisher Scientific is committed to a continuing program of product development and improvement, and reserves the right to change information, such as specifications, appearance, and dimensions, described in this document without notice.
Make sure to take out vibration and noise. 1.1 Packing List Table -1 Packing List Description Figure NA Cat.No. NA/EU Cat.No. 88861048 88861047 /15514080 Multi Function Rotator US plug Intl plug *Dimpled Rubber Mat General Power Adaptor US Plug CN Plug...
Application Environmental Conditions: indoor use Description Temperature NA Cat.No. NA/EU Cat.No. 5 to 40℃(41 to 104℉) Humidity 20% to 85%, 88861048 88861047 /15514080 Multi Function Rotator ≤2,000 m US plug Altitude Intl plug ±10% of the nominal voltage Voltage Fluctuation...
Position of Loads Place the loads in the recommended positions below: Warning: It may affect normal operation of the 1. Place load at the center of the tray instrument and even cause damage if loads are 2. Place loads symmetrically around the center of the tray placed asymmetrically.
Section 3 Operation This chapter covers the control panel and its operation. 3.1 Control Panel ⑤ ① ② ③ ④ Vibrate ⑥ ⑦ ⑧ ⑨ ⑩ The front panel of the Multi Function Rotator contains all the controls needed to operate the unit. 1.
3.3 Settings 4.2 Press “ ”or “ ” on the right to set time needed. 1. Single mode continuous operation 1.1 Press “ ”to select 4.3 After setting one operation mode, press “ ”again to operation mode needed and the corresponding indicator switch to another mode indicated by the corresponding light will be on.
Section 4 Safety Tips and Maintenance Safety Tips Clean Spill 1. Use independent power supply. If accidental spillage of liquids caused by mishandling or 2. Check if the local power supply voltage is suitable for use. contained breakage occurs on the surface of the 3.
Replace power adaptor Adjust the weight and position of load, Over-weighted or unbalanced load decrease rotation speed No shaking of the tray Electrical malfunction Contact Fisher Scientific Mechanical malfunction Contact Fisher Scientific Machine case loose Fasten machine case screws Tray loose...
Section 6 Optional Spare Parts Description EU Cat. No. Max. Qty Figure NA Cat. No. Dimensions Dimpled Rubber Mat 88861198 15594130 298×258mm 180×7mm (6pcs/pack) Rubber Strips 88861178 15594120 AC 100 240V, 50/60HZ General Power Adaptor 88861154 15554120 Power Cable US Plug 125VAC, 10A, 1.8m 88861155 Power Cable CN Plug...
When used in laboratory conditions and according to these operation instructions and maintenance, this product is warranted for 24 months against defective materials or workmanship. The 24 month warranty period begins from the delivery date of this product. For product quality or performance issues, contact Fisher Scientific Customer Service.
Page 14
North America United States Canada 1-800-766-7000 1-800-234-7437 fishersci.com fishersci.ca Europe Austria: Netherlands: +43(0)800-20 88 40 +31(0)20 4887 70 00 at.fishersci.com nl.fishersci.com Belgium: Norway: +32(0)56 260 260 +47 22 95 59 59 be.fishersci.com fishersci.no Denmark: Portugal: +45 70 27 99 20 +351 21 425 33 50 fishersci.dk pt.fishersci.com...