Vertical Venting With Two 90; Elbows - HAMPTON BAY H35U-NG Owners & Installation Manual

Table of Contents

Advertisement

Vertical Venting with Two 90

Option
V
A)
1' (305 mm) min.
B)
2' (610 mm) min.
C)
3' (914 mm) min.
D)
4' (1.2 m) min.
E)
5' (158 m) min.
Lengths do not include elbow indicated
Vent restrictor position A (fully open) Refer to the "Vent Restrictor Position" section.
Vertical Venting with Two 90
One 90
Option
H + H1
A)
2' (610 mm) max.
B)
3' (914 mm) max.
C)
4' (1.2 m) max.
D)
5' (1.5 m) max.
E)
6' (1.8 m) max.
Lengths do not include elbow indicated
Vent restrictor position A (fully open) Refer to the "Vent Restrictor Posi-
tion" section.
Hampton® H35U Direct Vent Freestanding Gas Stove

Elbows

o
One 90
elbow = Two 45
elbows.
o
o
H
V + V1
3' (914 mm) max.
2' (610 mm) min.
4' (1.2 m) max.
3' (914 mm) min.
5' (1.5 m) max.
4' (1.2 m) min.
6' (1.8 m) max.
5' (1.5 m) min.
7' (2.1 m) max.
6' (1.8 m)
Elbows
o
elbow = Two 45
elbows.
o
o
V
With these options, max.
total pipe length is 30 feet
2' (610 mm) min.
with min. of 9 feet total ver-
tical and max. 8 feet total
3' (914 mm) max.
horizontal.
4' (1.2 m) max.
Please note minimum 1
5' (1.5 m) min.
foot between 90
is required.
6' (1.8 m) min.
With these options, max.
total pipe length is 30 feet
with min. of 9 feet total ver-
tical and max. 8 feet total
horizontal.
Please note minimum 1
foot between 90
elbows
o
is required.
elbows
o
V
H1
installation
H