VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two3"(76mm)co-linearaluminiumflexrunning
thefulllengthofthechimney.SeetheVenting
Arrangements chart below for minimum and
maximum flue lengths. See chart below for
minimumdistancesfromroof.Periodicallycheck
thattheventisunrestricted.
Venting Arrangements - Vertical Terminations
with Co-linear Flex System for both
Residential & Manufactured Homes
into Masonry Fireplaces
The shaded area in the diagram shows the allowable vertical
terminations.
Straight Vertical Terminations
Vent Restrictors
set at fully closed,
Position "B"
Masonrychimneysmaytakevariouscontourswhichtheflexiblelinerwillaccommodate.However,keep
the flexible liner as straight as possible,avoidunnecessarybending.
TheAirIntakepipemustbeattachedtotheinletaircollaroftheterminationcap.
Required Parts:
Part #
Description
946-529
Co-linearDVVertical
TerminationCap
948-305
3"Flex-35ft.
946-563
C o-AxialtoCo-LinearAdapterKit
whichcontainsthefollowing:
Co-linearFlexAdapter(270-585)
OuterPipe(946-257)
InnerPipeAdapter(946-219)
Alternate Approved Caps
46DVA-VC
46DVA-VCH
46DVA-GK
Hampton®H15E-11DirectVentFreestandingGasStove
installation
VerticalTerminationCap
HighWindCap
3 " C o - l i n e a r A d a p t e r
withflashing
|