Inductive Proximity Switch - WAMGROUP VCP R03 Series Assembly And Main Instructions For Use And Maintenance

Hide thumbs Also See for VCP R03 Series:
Table of Contents

Advertisement

5.8 Inductive proximity switch

The VCP valve in all its sizes can be provided with an inductive signalling system.
This device signals the opening of the valve in overpressure or negative pressure at the prefixed calibration
value.
WAM
supplies the KXS1 inductive sensor (which can operate with a 24 voltage at 220V - see attached techni-
®
cal sheet).
During valve activation phase, the sensor generates an instantaneous signal so that the valve returns to the
home position after the action. Use a control panel that maintains this signal.
The KXS1 sensor that detects the disc opening correctly must be positioned at a distance from the metallic
surface of 0 < H < 4 (mm) by means of the two nuts.
- M18 x 1 threaded cylinders
- Standard brass metal casing
- AC or DC power supply
length (mm):
a = all out
b = threaded
5.0 INSTALLATION AND FIXING
a = 60
b = 51.5
VCP
29
VAL.VCP.--.M.A5.1017.EN
10.17
2