VIRTUAL PATCH

Virtual Patch allows you to assign modulation sources such
as EG and LFO to various parameters.
Four such combinations can be made for each timbre.

Page14: PATCH1

Page15: PATCH2

Page16: PATCH3

Page17: PATCH4

A: Source
SOURCE ...........................[EG 1...MIDI 2]
Select a modulation source.
EG 1/EG 2
EG1 or EG2 will be the modulation source.
LFO 1/LFO 2
LFO1 or LFO2 will be the modulation source.
Velocity
Keyboard playing dynamics will be the modulation
source.
KBD Trk
Keyboard location (keyboard tracking) will be the modu-
lation source.
Keyboard Track operates according to the pitch that is
controlled by pitch bend, transpose, and Mod Sequence.
It is not affected by pitch changes produced by vibrato
or Virtual Patch.
MIDI 1/MIDI 2
The function specified in Global mode Page 3D: MIDI
"MIDI 1" or Page 3E: MIDI "MIDI 2" will be the modula-
tion source.
B: Destination
DESTINATION ........ [Pitch...LFO2Freq]
Select the parameter (destination) that will be controlled by
the modulation.
Pitch
Modulation will apply to the pitch of the entire timbre.
OSC2Ptch
Modulation will apply to the Page 06D: OSC2 "Tune"
parameter.
OSC1Ctr1
Modulation will apply to the Page 05B: OSC1 "Control 1"
parameter.
NoiseLvl
Modulation will apply to the Page 07C: MIXER
"NoiseLevel" parameter.
Cutoff
Modulation will apply to the Page 08B: FILTER "Cutoff"
parameter.
Amp
Modulation will apply to the Page 09A: AMP "Level"
parameter.
42
Pan
Modulation will apply to the Page 09B: AMP "Panpot"
parameter.
LFO2 Freq
Modulation will apply to the Page 13D: LFO2 "Frequency"
parameter.
If LFO "Tempo Sync" is ON, selecting LFO2Freq will
have no effect.
C: Intensity
PATCH ................................. [–63...+63]
Specify the depth of the effect produced by the modulation
source.
With a setting of 0, there will be no modulation.

MOD SEQUENCE

These are the sequence-related parameters.

Page18: SEQ COMMON

A: Last Step .................................................... [01...16]
Specify the sequence length (maximum number of steps).
B: Seq Type ........................................ [Forward...Alt 2]
Specify the sequence type (sequence playback direction)
Forward
Play back from the first step (Step 01).
Forward (Last Step=16)
Step
Step
Step
01
02
03
Run Mode=Loop
Reverse
Play back in reverse, from the last step (the value specified
by "Last Step").
Reverse (Last Step=16)
Step
Step
Step
16
15
14
Run Mode=Loop
Alt 1/Alt 2
Alternately play back in Forward and Reverse.
Alt1 (Last Step=16)
Step
Step
01
02
Run Mode
Step
Step
=Loop
01
02
Alt2 (Last Step=16)
Step
Step
01
02
Run Mode
=Loop
Step
Step
01
02
During Motion Rec, the sequence will always play in
Forward mode.
Step
Step
Step
14
15
16
Step
Step
Step
03
02
01
Step
Step
15
16
Step
15
Step
Step
15
16
Step
Step
15
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms2000

Table of Contents