Technical Reference Manual
Table 4.1.15-2 Recorded data: Channel 0
Recorded data
Parameter (R) Value
Trip target code
Start-up time of the
latest motor start up
Number of pickups of
element (48/14
2
PICKUP)
x (48/14
TDLY) or 48/14
Number of pickups of
element 50P
Number of pickups of
element 51N
Number of pickups of
element 37
Number of pickups of
element 46
The last five recorded values can be read with parameters V1...V28 on channels
1...5. Event n denotes the last recorded value, n-1 the next one, and so forth.
Table 4.1.15-3 Recorded data: Channels 1...5
Recorded data
n
Channel 1
Phase current I
1V1
a
Phase current I
1V2
b
Phase current I
1V3
c
V2
0 = ---
1 = alarm of element 49
2 = trip of element 49
3 = pickup of element (48/14 PICKUP)
TDLY) or 48/14
4 = trip of element (48/14 PICKUP)
or 48/14
5 = pickup of element 50P
6 = trip of element 50P
7 = pickup of element 37
8 = trip of element 37
9 = pickup of element 51N
10 = trip of element 51N
11 = pickup of element 46
12 = trip of element 46
13 = trip of element 46R
14 = external trip
15 = alarm of element 49/38-1
16 = trip of element 49/38-1
17 = alarm of element 49/38-2
18 = trip of element 49/38-2
19 = restart disable (49)
20 = restart disable (66)
21 = restart disable (external)
22 = CBFAIL
V3
0...240 s
V4
0...999
V5
0...999
V6
0...999
V7
0...999
V8
0...999
Event (R)
n-1
n-2
Channel 2
Channel 3
2V1
3V1
2V2
3V2
2V3
3V3
1MRS 755537
2
x (48/14
2
x (48/14 TDLY)
Value
n-3
n-4
Channel 4
Channel 5
4V1
5V1
0...50 x FLA
4V2
5V2
0...50 x FLA
4V3
5V3
0...50 x FLA

Advertisement