7.8. ESD
The module is not protected against electrostatic discharge (ESD) in general. Consequently, it should be
subject to ESD handling precautions that are typically applied to ESD sensitive components. Proper ESD
handling and packaging procedures must be applied throughout the processing, handling and operation
of any application that incorporates the module.
The following table shows the electrostatic discharge characteristics of the SC20 series.
Table 67: ESD Characteristics (Temperature: 25 ºC, Humidity: 45 %)
Tested Interfaces
VBAT, GND
All Antenna Interfaces
USB Interface
Other Interfaces
SC20_Series_Hardware_Design
Contact Discharge
±5
±5
±0.5
±0.5
Air Discharge
±10
±10
±1
±1
Smart Module Series
Unit
kV
kV
kV
kV
122 / 133