Rough-in

The VSE2 fits into most 18 cu. in. rough-in boxes. DO NOT install
the VSE2 in the same electrical box as high-voltage (110, 240VAC)
devices such as dimmers, light switches, etc. as these devices will
cause harmful interference and create buzzing, humming, or other
audio interference. Close proximity to high-voltage devices can
also cause undesired IR operation.
Like any IR device, the VSE2's IR receiver is susceptible to
interference from ambient light, sunlight, or plasma television
radiation. Please do not mount the unit in locations susceptible to
these conditions.
Note: The VSE2 is not warranted for outdoor installation.

Wiring

Four-conductor speaker wire and Cat-5 cable should be run
from the main equipment location where the system's amplifier
is located to the mounting location for each VSE2. The speaker
terminals on this unit will accommodate 14 to 24 AWG stranded
copper speaker wire. Runs that exceed 150 feet should use
heavier gauge wire, but 16 or 18 AWG is usually sufficient. Check
local building codes for specific guidelines regarding in-wall wire
runs. Cat-5 cable is required when installing this unit to provide
Power, Override, Sense Input, IR In, and IR Out. This unit must be
connected to power in order to function.