4) Loosen the screw [6] on the tension arm
plate [5]. (The tension arm plate will be
pulled under tension by the tension
spring.)
5) Keeping the sheet as it is, move the
returning roller shaft [7] to its lower limit;
then, tighten the screw [6] on the tension
arm plate [5].
COPYRIGHT © 1999 CANON INC.
CANON FINISHER-E1 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 5 TROUBLESHOOTING
[6]
[5]
Figure 5-115
[6]
[5]
Figure 5-116
[7]