Download Print this page

Canon FINISJER-E1 Service Manual page 126

Advertisement

CHAPTER 5 TROUBLESHOOTING
4) Measure the jogging width (standard at
317 mm).
5) Remove the processing tray. (Figures 3-
301 through -306)
6) Loosen the screw [2] on the home position
sensor plate [1] at the front.
7) Adjust the position of the front jogging
plate home position sensor (S6) with
reference to the index.
EX 1
If the width is 319 mm in step 2), the
difference from the standard is +2 mm,
requiring relocation of the sensor [3] in
the direction of arrow A by 2 mm.
EX 2
If the width is 316 mm in step 2), the
difference from the standard is -1 mm,
requiring relocation of the sensor [3] in
the direction of arrow B by 1 mm.
Reference:
A guide [4] is provided on the back of the
inside right cover (standard alignment width
of 317 mm). You may fold large-size paper in
reference to the guide, and use the result when
measuring the jogging plate width.
5-2
COPYRIGHT © 1999 CANON INC.
Figure 5-104
A
B
Figure 5-105
Inside right cover
Figure 5-106
CANON FINISHER-E1 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[2]
[3]
[4]
317mm
Large-size paper
[1]

Advertisement

loading