Set Clock; Service Menu - Truma CP plus Operating Instructions Manual

Table of Contents

Advertisement

• Select the desired energy mode with the ro-
tary push button (8).
• Tap the rotary push button (8) to confirm the
value.
Select fan level
For more information „Select fan level" auf
Page 7.
• Select the desired fan level with the rotary
push button.
• Tap the rotary push button to confirm the
value.
Enable time switch ("ON")
• Enable the time switch (ON) with the rotary
push button
• Tap the rotary push button to confirm the
value.
The time switch remains enabled, even for
several days, until it is disabled (OFF).
If the time switch is programmed and
enabled, the time switch icon flashes
(Fig. 12 – 1).
Fig. 12
Disable time switch ("OFF")
• Tap the rotary push button to go to the set-
ting level.
• Disable the time switch (OFF) with the rotary
push button
• Tap the rotary push button to confirm the
value.
Fig. 13
Display 24 h mode
Fig. 14
• Use the rotary push button (Fig. 1 – 8) to
The hour display flashes.
• Use the rotary push button (Fig. 1 – 8) to set
• Tap the rotary push button again and the
• Use the rotary push button to set the
• Tap the rotary push button to confirm the
1
1. Calibrating the room temperature sensor
of the Combi (D) ("OFFSET")
The room temperature sensor of the connected
Combi (D) can be adjusted individually to suit
the location of the sensor. Settings can be made
in the range from 0 °F to -10 °F (0 °C to -5 °C) in
1 °F (0.5 °C) increments.
Fig. 16
Default setting: 0 °F (0 °C).
2. AC SET
(Only available if ACC is set to "ON")
The sensed room temperature can – during
operation of the automatic climate control – be
perceived differently during cooling than during
heating. "AC SET" is used to set an offset be-
tween cooling and heating. The setting can be
made in increments of 1 °F (0.5 °C) within the
range of 0 °F to 10 °F (0 °C to 5 °C).

Set clock

4
Fig. 15
select the "Set clock" icon in the menu
line (Fig. 14 & 15 – 4).
the hours.
minute display flashes.
minutes.
value.

Service menu

Example:
Set room temperature 75 °F;
OFFSET = -1 °F;
Setpoint for Combi (D) = 74 °F
Display 12 h mode
4
= a. m.
= p. m.
9