Page 1
Truma CP (E) classic Gebrauchsanweisung Seite Einbauanweisung Seite 11 Im Fahrzeug mitzuführen! Operating instructions Page 13 Installation instructions Page 22 To be kept in the vehicle! Mode d‘emploi Page 24 Instructions de montage Page 33 À garder dans le véhicule ! Istruzioni per l‘uso...
Gas or diesel mode .............. 17 The room temperature and the water temperature can be set Electrical mode ..............18 at a Truma Combi (E) heating system using the control panel. Mixed mode ................ 18 Accessories ............... 18 Power selector switch – CP E classic Troubleshooting guide (Combi Gas heating system) .
Display and control panels i = Power selection rotary switch j = Electrical mode 230 V, 1800 W Control panel – CP classic k = Electrical mode 230 V, 900 W l = Gas or diesel mode m = Mixed mode* (gas, diesel or electrical mode 900 W)
Start-up Heating and hot water mode Heating mode is possible with or without water Devices with electrical heating elements content depending on the operating mode. Select gas, diesel, electrical or mixed mode using the power selector switch. Illumination of the yellow LED (o) at the power selector switch indicates that the unit is operating Hot water mode with 230 V.
Switching off The unit automatically selects the required operating level according to the temperature difference between the setting on the control panel and the current room temperature. Once Switch off heating system at control panel using rotary switch the room temperature selected on the control panel has been (position f).
Line-up clip, 1 piece (part no. 34000-65900). For installing sev- Possible causes can be found in the troubleshooting guide. eral Truma control panels next to each other. If the 230 V power supply is interrupted during mixed mode, the heating system will automatically switch to gas mode.
Troubleshooting guide (Combi Gas heating system) Flashing code at analogue control panel – CP Classic Flash sequence LED: – On / Off: 0.5 seconds Pause between flash sequence: seconds Fault Cause Rectification No LED is on, the unit is switched –...
Page 8
– No fault. After-run switches itself off after max. 5 minutes adjustment immediately the temperature of the unit After switching on the green and – Faulty electronics – Please contact Truma Service the red LED illuminate If these actions do not remedy the problem, please contact Truma Service.
Troubleshooting guide (Combi Diesel heating system) Flashing code in analogue control panel – CP Classic Flash sequence LED: – On / Off: 0.5 seconds Pause between flash sequence: 5 seconds Fault Cause Rectification No LED illuminates – No operating voltage –...
Page 10
– Please contact Truma Service cable defective Yellow LED flashes 8 x – FrostControl heating element – Disconnect heating element plug from electronic control unit, has a short circuit replace heating element If these actions do not remedy the problem, please contact Truma Service.
Technical data Dimensions (LxWxH) 53 x 53 x 44 mm Right reserved to make technical changes! Maintenance The control panels are maintenance free. Disposal The unit must be disposed of in line with the administrative regulations of the respective country in which it is used. National regulations and laws (in Germany, for example, the End-of-life Vehicle Regulation) must be observed.
In order to avoid delays, please have the unit model and factory number ready (see type plate). Veuillez vous adresser au centre de SAV Truma ou à un de nos partenaires de SAV agréés en cas de dysfonctionnements (consultez votre livret de service Truma ou www.truma.com).