MAD / MAF Asynchronous Housing Motors
Parameter
Pressure drop at Q
min
Constant for determining the pres‐
sure drop with water as cooling me‐
dium
Required coolant flow for P
V
Coolant channel volume
Maximum allowed input pressure
4.9.4
Motor characteristic curves MAF130C
Symbol
Unit
0050
Δp
bar
K
-
Δp
Q
l/min
3.1
min
V
l
cool
p
bar
max
1)
Please note the information on the specified parameters at the
beginning of this chapter
Tab. 4-26:
MAF130C - Technical data
Fig. 4-76:
Motor characteristic curve MAF130C-0050
MAF130C
0100
0150
0200
0.2
0.02
3.3
0.20
6.0
R911295781_Edition 11 Bosch Rexroth AG
83/265
Technical data
0250
3.4