174/265
Connection techniques
8.2.2

Additional ground conductor on motors

Source: Rotating electrical ma‐
chines - DIN EN 60034-1
8.3

Power connection with connector socket

8.3.1

Motors with connector socket

MAD/MAF ...
100
130 ... 160
180 ... 225
Bosch Rexroth AG R911295781_Edition 11
Pursuant to EN 60034-1:2004 (11.1 Grounding of machines), motors of frame
size MAF225C-0150 have to be grounded with an additional ground conduc‐
tor having a wire cross-section of at least 25 mm².
To achieve this, the motor flange is provided with a connection screw with an
M12 thread. Use this connection screw to attach the additional ground con‐
ductor to the motor by means of a ring terminal for M12 threads and connect
the cable to the ground bus in the control cabinet.
Device connector
INS480
INS380
Not available
Tab. 8-1:
Overview of motors with connector socket
Ready-made Rexroth power cables with coupling for connection of MAD/MAF
motors feature a bayonet lock.
Fig. 8-1:
Plug-in power connection
Proceed as follows to connect motors with connector socket:
1. Push the coupling into the connector socket and observe the coding.
2. Manually tighten the union nut until it can be heard clicking into place.
3. The marker points on the coupling and the connector socket have to be
opposite to each other with the bayonet lock clicked into place.
MAD / MAF Asynchronous Housing Motors
Terminal range
Coupling
[mm²]
INS048x
1.5 ... 10
INS038x
6 ... 35
-/-
1
2
INS0380
INS0381
Current carrying capaci‐
ty
max. 41 A
max. 100 A
-/-
-/-
3
CLICK