MAD / MAF Asynchronous Housing Motors
Parameter
Permissible coolant temperature in‐
crease for P
V
Pressure drop at Q
min
Constant for determining the pres‐
sure drop with water as cooling me‐
dium
Required coolant flow for P
V
Coolant channel volume
Maximum allowed input pressure
4.9.2
Motor characteristic curves MAF130B
Symbol
Unit
0050
ΔT
K
max
Δp
bar
K
-
Δp
Q
l/min
2.6
min
V
l
cool
p
bar
max
1)
Please note the information on the specified parameters at the
beginning of this chapter
Tab. 4-25:
MAF130B - Technical data
Fig. 4-71:
Motor characteristic curve MAF130B-0050
MAF130B
0100
0150
0200
10
0.1
0.02
2.7
2.9
0.15
6.0
R911295781_Edition 11 Bosch Rexroth AG
79/265
Technical data
0250
3.2