7.2. Setting functions

7.2.1.

Bit allocation BA=0, BA=1

This command sets the output for either 8-bit or 10-bit.
7.2.2.

Partial scan SC=0 through 4.

The CCD scanning format can be selected between full or partial scanning. With partial scanning
only the vertical central part of the CCD sensor is read out with a higher frame rate. The partial
scan is done by a fast dump read out of the lines in the vertical CCD register down to the top of
the partial image. This central part of the image is read out with normal speed. The lines below
the partial image are read out and dumped with a high speed.
Note: The color sequence for CB-200 MCL differs in partial scan modes. Refer to chapter 6.1.7.
7.2.3.
Vertical binning
This function is only for CM-200MCL camera.
With Vertical binning the pixel charge from 2 adjacent lines are added together in the horizontal
CCD register. This done by providing two pulses to the vertical CCD register for each line readout.
Note : Vertical Binning can not be used together with the Partial scanning.
7.2.4.

Shutter mode SM=0 and SM=1

With SM=0 this function selects the shutter from the 10 fixed steps (SH=0 through SH=9).
With SM=1 from programmable in 1251 steps (PE=2 through PE=1252).
7.2.5.

Trigger input select TI=0, TI=1.

This function selects the trigger input to be through Camera Link (TI=0), or as TTL through the 12
pin Hirose connector (TI=1).
7.2.6.

Trigger polarity. TP=0, TP=1.

The active trigger polarity is normal low (TP=0). It can be invert it to active high (TP=1).
6
7.2.7.

Gain level GA= -84 through +336.

GA=0 is 0dB gain, which is normal working point. The range is from -3 dB to +12 dB.
7.2.8.

Black level BL=0 through BL=1023.

Black level (or set-up level) will set the video level for black. Factory setting is 32 LSB for 10bit or
8 LSB for 8bit.

7.3. Save and Load Functions.

The following commands are for store and load camera settings in the camera EEPROM.
Load settings LD
CM-200 MCL / CB-200 MCL
VB=0, VB=1
- 20 -