Electrical Connection (Required) - Lopi 864 TRV 31K CleanFace Manual

Table of Contents

Advertisement

Finalizing the Installation

Electrical Connection (required)

The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified
installer and must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical lines.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The electrical line must be a min. 14 gauge, and supply 240 Volts at 60 Hz (2 Amps).
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
a
© Travis Industries
b
6/27/2019 - 1500
(for qualified installers only)
c
21
d
864 31K CF Aust