Rear Vent Configuration With Vertical Termination - Lopi 864 TRV 31K CleanFace Manual

Table of Contents

Advertisement

30
Finalizing the Installation

Rear Vent Configuration with Vertical Termination

The termination must
fall within the shaded
area shown in the
chart. Use the
indicated restrictor
and diffuser positions.
Up to four elbows
(45° or 90°) may be
used.
Only one horizontal
elbow may be used.
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
© Travis Industries
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
H2
H1
6/27/2019 - 1500
(for qualified installers only)
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).