5.3.1

GROUNDING OF THE POWDER COATING SYSTEM

1
2
P_01120
1
Only use mains cables with grounding wire!
2
Connect grounding cable with booth and system ground!
3
Connect grounding cable to an uncoated metal part of the booth!
4
Remove all paint from hooks and other hanger parts!
5
Do not wear non-conducting gloves!
6
Wear electrostatically conductive shoes!
7
The fl oor must be electrostatically conductive!