1. MOUNTING
Flush mounting
Use the optional flush mount kit FP03-09870 to mount the control unit RCU-014, RCU-015
and/or RCU016 to a console panel.
Name: Flush mount kit
Type: FP03-09870
Code No.: 008-535-630
No.
Name
1
Mount plate
2
Hex nut
3
Wing screw
4
Pan head screw
1. Prepare a cutout in the mounting location as shown in the figure below.
For RCU-014
2. Set the control unit to the cutout.
3. Attach the mounting plate to the control unit with four screws from the rear side.
4. Screw the wing screw to each mounting plate and then insert hex bolt to each wing
screw.
5. Fasten each wing screw and then fasten the hex nuts as shown in the figure below.
#70
RCU-014
1-12
Type
03-163-7531
M5
M5x40
M4x12
±2
388
Note:
Code No.
100-306-261
000-863-108
000-162-682-10
000-163-192-10
170±2
For RCU-015 and RCU-016
#70
< =
P 10
RCU-015/RCU-016
Qty
4
4
4
4
176±2
150±2
171