3. SETTING AND ADJUSTMENT

3.1

DIP Switch Setting

The processor unit is shipped for model FAR-2117 or FAR-2127. If your model is FAR-2817/
2827/2117-BB/2127-BB, change the DIP switch setting as follows.
1. Remove the top cover of the processor unit.
2. Open the SPU assembly block.
3. Set the DIP switch S1 as follows.
OFF
ON
1
2
3
4
S1
Note: Set #1 and #2 of S1 to OFF for MU-231CR S. No. 0268 and earlier.
Shield cover
S1
Monitor SXGA for
FAR-2117/2127
(Default)
1
OFF
2
OFF
3
4
SPU assembly block
SPU board 03P9337
DIP switch S1
Monitor UXGA for
FAR2817/2827
(MU-231CR
S. No. 0269 and later)
ON
OFF
Not used.
FAR-2117-BB
FAR-2127-BB
OFF
ON
3-1