SPECIFICATIONS
7.1.2 600 V AC power input
Model FR-A870-
SLD
*1
Applicable motor capacity [kW]
ND (initial setting)
SLD
*2
Rated capacity [kVA]
ND (initial setting)
SLD
*3
Rated current [A]
ND (initial setting)
SLD
*4
Overload current rating
ND (initial setting)
*5
Rated voltage
*6
Brake transistor
Regenerative braking
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
SLD
*7
Rated input current [A]
ND (initial setting)
SLD
*8
Power supply capacity [kVA]
ND (initial setting)
*9
Protective structure (IEC 60529)
Cooling system
*10
Noise level [dB]
Approx. mass [kg]
*1
Indicates the maximum capacity applicable to voltage of 575 V.
*2
The rated output capacity indicated assumes that the output voltage is 575 V.
*3
Possible output currents during continuous operation under Real sensorless vector control or Vector control are shown in the table below.
PWM carrier frequency
SLD
1 kHz
230 A
2 kHz
191 A
3 kHz
154 A
4 kHz
115 A
The PWM carrier frequency is automatically decreased to 2 kHz for heavy duty applications when operating the motor under Real sensorless vector control or
Vector control with a PWM carrier frequency of 6 kHz or more (Pr. 72
*4
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the
inverter and motor to return to or below the temperatures under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the
maximum point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about 2.
*6
Built-in brake transistor model only. For the resistance, refer to the FR-A870 Instruction Manual (Hardware).
*7
The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and cables) affects
the rated input current.
*8
The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input reactor
and cables).
*9
FR-DU08: IP40 (except for the PU connector section)
*10
Values measured 1 m in front of the inverter and 1.6 m from the floor.
42
02300
132
110
229
184
230
185
110 % of rated motor capacity for 60 s, 120 % of rated motor capacity for 3 s (max. surrounding air temperature 40 °C)
150 % of rated motor capacity for 60 s, 200 % of rated motor capacity for 3 s (max. surrounding air temperature 40 °C)
Three-phase 525 to 600 V
Built-in
Three-phase 525 to 600 V 50 Hz/60 Hz
472 to 660 V 50 Hz/60 Hz
±5 %
230
185
229
184
Enclosed type (IP20)
Forced air cooling
79
120
02300
ND
SLD
185 A
286 A
159 A
237 A
133 A
192 A
107 A
143 A
6). The carrier frequency stays at 4 kHz in fast-response operation.
02860
160
132
285
229
286
230
286
230
285
229
79
122
02860
ND
230 A
198 A
166 A
133 A