Download Print this page

Mitsubishi Electric 800 Series Assembly & Installation Manuallines page 13

Hide thumbs Also See for 800 Series:

Advertisement

*1
When using separate power supply for the control circuit, remove the jumper between R1/L11 and S1/L21.
*2
The function of these terminals can be changed with the input terminal assignment (Pr. 178 to Pr. 189). (Refer to page 23.)
*3
Terminal JOG is also used as the pulse train input terminal. Use Pr. 291 to choose JOG or pulse.
*4
Terminal input specifications can be changed by analog input specification switchover (Pr. 73, Pr. 267). To input a voltage, set the voltage/
current input switch OFF. To input a current, set the voltage/current input switch ON. Terminals 10 and 2 are also used as a PTC input terminal.
(Pr. 561) (Refer to the FR-A870 Instruction Manual (Function).)
*5
It is recommended to use 2 W, 1 kΩ when the frequency setting signal is changed frequently.
*6
The function of these terminals can be changed with the output terminal assignment (Pr. 195, Pr. 196). (Refer to page 23.)
*7
The function of these terminals can be changed with the output terminal assignment (Pr. 190 to Pr. 194). (Refer to page 23.)
*8
The terminal F/C(FM) can be used to output pulse trains as open collector output by setting Pr. 291.
*9
Not required when calibrating the scale with the operation panel.
*10
The option connector 2 cannot be used because the Ethernet board is installed in the initial status. The Ethernet board must be removed to
install a plug-in option to the option connector 2. (However, Ethernet communication is disabled in that case.)
*11
Connect a brake resistor to terminals P/+ and PR (built-in brake transistor model only). Install a thermal relay to prevent overheating and
damage of the brake resistor.
CAUTION
To prevent a malfunction due to noise, keep the signal cables more than 10 cm away from the power cables. Also, separate the main circuit
cables at the input side from the main circuit cables at the output side.
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean.
When drilling mounting holes in a control box etc., take care not to allow chips and other foreign matter to enter the inverter.
Set the voltage/current input switch in the correct position. An incorrect setting may cause a fault, failure or malfunction.
For the parameter details, refer to the FR-A870 Instruction Manual (Function).
WIRING