BASIC OPERATION
Parameter Name
57
Restart coasting time
58
Restart cushion time
Remote function
59
selection
Energy saving control
60
selection
61
Reference current
Reference value at
62
acceleration
Reference value at
63
deceleration
Starting frequency for
64
elevator mode
65
Retry selection
Stall prevention
66
operation reduction
starting frequency
Number of retries at
67
fault occurrence
68
Retry waiting time
Retry count display
69
erase
Special regenerative
70
brake duty
71
Applied motor
PWM frequency
72
selection
73
Analog input selection
Input filter time
74
constant
Reset selection/
disconnected PU
75
detection/PU stop
selection
Fault code output
76
selection
Parameter write
77
selection
Reverse rotation
78
prevention selection
Operation mode
79
selection
Simple
Simple
Simple
80
Motor capacity
Number of motor
81
poles
Motor excitation
82
current
83
Rated motor voltage
Rated motor
84
frequency
Excitation current
85
break point
Excitation current low
86
speed scaling factor
Speed control gain
89
(Advanced magnetic
flux vector)
90
Motor constant (R1)
*1
Differs according to types. (FM type/CA type)
24
Setting range
Initial value
0, 0.1 to 30 s,
9999
9999
1 s
0 to 60 s
0
0 to 3, 11 to 13
0
0, 4, 9
9999
0 to 3600 A, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 10 Hz, 9999
0 to 5
0
*1
0 to 590 Hz
60/50 Hz
0 to 10,
0
101 to 110
1 s
0.1 to 600 s
0
0
0%
0 to 100%
0
0 to 6, 13 to 16
*2
2
0 to 6, 25
1
0 to 7, 10 to 17
1
0 to 8
0 to 3, 14 to 17,
100 to 103,
114 to 117,
14
1000 to 1003,
1014 to 1017,
1100 to 1103,
1114 to 1117
0 to 2
0
0
0 to 2
0
0 to 2
0
0 to 4, 6, 7
0 to 3600 kW,
9999
9999
2, 4, 6, 8, 10, 12,
9999
9999
0 to 3600 A,
9999
9999
690 V
0 to 1000 V
10 to 400 Hz,
9999
9999
9999
0 to 400 Hz, 9999
9999
0 to 300%, 9999
9999
0 to 200%, 9999
0 to 400 m ,
9999
9999
Parameter Name
91
Motor constant (R2)
Motor constant (L1)/d-
92
axis inductance (Ld)
Motor constant (L2)/q-
93
axis inductance (Lq)
94
Motor constant (X)
Online auto tuning
95
selection
Auto tuning setting/
96
status
100
V/F1 (first frequency)
V/F1 (first frequency
101
voltage)
V/F2
102
(second frequency)
V/F2 (second
103
frequency voltage)
V/F3
104
(third frequency)
V/F3 (third frequency
105
voltage)
V/F4
106
(fourth frequency)
V/F4 (fourth frequency
107
voltage)
108
V/F5 (fifth frequency)
V/F5 (fifth frequency
109
voltage)
Third acceleration/
110
deceleration time
Third deceleration
111
time
112
Third torque boost
Third V/F
113
(base frequency)
Third stall prevention
114
operation level
Third stall prevention
115
operation frequency
Third output
116
frequency detection
PU communication
117
station number
PU communication
118
speed
PU communication
119
stop bit length /
data length
PU communication
120
parity check
Number of PU commu-
121
nication retries
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication CR/
124
LF selection
Terminal 2 frequency
setting gain frequency
125
Simple
Simple
Simple
Setting range
Initial value
0 to 400 m ,
9999
9999
0 to 400 mH,
9999
9999
0 to 400 mH,
9999
9999
9999
0 to 100%, 9999
0 to 2
0
0
0, 1, 11, 101
9999
0 to 590 Hz, 9999
0 V
0 to 1000 V
9999
0 to 590 Hz, 9999
0 to 1000 V
0 V
9999
0 to 590 Hz, 9999
0 V
0 to 1000 V
9999
0 to 590 Hz, 9999
0 V
0 to 1000 V
0 to 590 Hz, 9999
9999
0 V
0 to 1000 V
9999
0 to 3600 s, 9999
9999
0 to 3600 s, 9999
9999
0 to 30%, 9999
9999
0 to 590 Hz, 9999
150%
0 to 400%
0 Hz
0 to 590 Hz
*1
0 to 590 Hz
60/50 Hz
0
0 to 31
48, 96, 192, 384,
192
576, 768, 1152
1
0, 1, 10, 11
2
0 to 2
0 to 10, 9999
1
0, 0.1 to 999.8 s,
9999
9999
9999
0 to 150 ms, 9999
1
0 to 2
*1
0 to 590 Hz
60/50 Hz