Parameter Name
Terminal 4 frequency
setting gain frequency
126
Simple
Simple
Simple
PID control automatic
127
switchover frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
Electronic bypass
135
sequence selection
MC switchover
136
interlock time
137
Start waiting time
Bypass selection at a
138
fault
Automatic switchover
frequency between
139
inverter and commer-
cial power-supply
operation
Backlash acceleration
140
stopping frequency
Backlash acceleration
141
stopping time
Backlash deceleration
142
stopping frequency
Backlash deceleration
143
stopping time
Speed setting
144
switchover
PU display language
145
selection
Acceleration/
147
deceleration time
switching frequency
Stall prevention level
148
at 0V input
Stall prevention level
149
at 10V input
Output current
150
detection level
Output current
151
detection signal delay
time
Zero current detection
152
level
Zero current detection
153
time
*1
Differs according to types. (FM type/CA type)
*3
The setting value "60" is only available for Pr. 178, and "61" only for Pr. 179.
*4
The setting is available when a vector control compatible option is installed. For the corresponding parameters of each option, refer to the
Instruction Manual of the option.
Setting range
Initial value
*1
0 to 590 Hz
60/50 Hz
9999
0 to 590 Hz, 9999
0, 10, 11, 20, 21,
40 to 43, 50, 51,
60, 61, 70, 71, 80,
0
81, 90, 91, 100,
101, 1000, 1001,
1010, 1011, 2000,
2001, 2010, 2011
0.1 to 1000%,
100%
9999
0.1 to 3600 s,
1 s
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
0.01 to 10.00 s,
9999
9999
0
0, 1
1 s
0 to 100 s
0.5 s
0 to 100 s
0
0, 1
0 to 60 Hz,
9999
9999
1 Hz
0 to 590 Hz
0.5 s
0 to 360 s
1 Hz
0 to 590 Hz
0.5 s
0 to 360 s
0, 2, 4, 6, 8, 10,
4
102, 104, 106,
108, 110, 112
0 to 7
0 to 590 Hz,
9999
9999
150%
0 to 400%
200%
0 to 400%
0 to 400%
150%
0 s
0 to 10 s
5%
0 to 400%
0 to 10 s
0.5 s
Parameter Name
Voltage reduction
154
selection during stall
prevention operation
RT signal function
155
validity condition
selection
Stall prevention
156
operation selection
157
OL signal output timer
AM terminal function
158
selection
Automatic switch-over
frequency range from
159
bypass to inverter
operation
User group read
160
selection
Simple
Simple
Simple
Frequency setting/key
161
lock operation selection
Automatic restart after
162
instantaneous power
failure selection
First cushion time for
163
restart
First cushion voltage
164
for restart
Stall prevention
165
operation level for
restart
Output current
166
detection signal
retention time
Output current
167
detection operation
selection
168
Parameter for manufacturer setting.
Do not make setting.
169
170
Watt-hour meter clear
Operation hour meter
171
clear
User group registered
172
display/batch clear
User group
173
registration
174
User group clear
STF terminal function
178
selection
STR terminal function
179
selection
RL terminal function
180
selection
RM terminal function
181
selection
RH terminal function
182
selection
RT terminal function
183
selection
BASIC OPERATION
Setting range
Initial value
1
0, 1, 10, 11
0
0, 10
0
0 to 31, 100, 101
0 to 25 s, 9999
0 s
1 to 3, 5 to 14, 17,
18, 21, 24, 32 to
1
34, 36, 50, 52 to
54, 61, 62, 67, 70,
87 to 90, 91 to 98
9999
0 to 10 Hz, 9999
0
0, 1, 9999
0
0, 1, 10, 11
0
0 to 3, 10 to 13
0 s
0 to 20 s
0%
0 to 100%
150%
0 to 400%
0.1 s
0 to 10 s, 9999
0
0, 1, 10, 11
9999
0, 10, 9999
9999
0, 9999
9999, (0 to 16)
0
9999
0 to 1999, 9999
9999
0 to 1999, 9999
60
0 to 9,
12 to 20,
61
22 to 28, 31, 32,
37, 41 to 48,
50 to 53,
0
*3
57 to 59, 60
,
*3
61
, 62,
1
64 to 69, 72 to 74,
76 to 80, 85,
2
87 to 89, 92 to 96,
*4
9999