BASIC OPERATION
Parameter Name
AU terminal function
184
selection
JOG terminal function
185
selection
CS terminal function
186
selection
MRS terminal function
187
selection
STOP terminal
188
function selection
RES terminal function
189
selection
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
232
Multi-speed setting
to
(speeds 8 to 15)
239
Soft-PWM operation
240
selection
Analog input display
241
unit switchover
Terminal 1 added
242
compensation amount
(terminal 2)
Terminal 1 added
243
compensation amount
(terminal 4)
Cooling fan operation
244
selection
245
Rated slip
Slip compensation
246
time constant
Constant-power range
247
slip compensation
selection
Self power manage-
248
ment selection
Earth fault detection
249
at start
250
Stop selection
Output phase loss
251
protection selection
252
Override bias
253
Override gain
*1
Differs according to types. (FM type/CA type)
*4
The setting is available when a vector control compatible option is installed. For the corresponding parameters of each option, refer to the
Instruction Manual of the option.
*5
The setting values "92", "93" and "192", "193" are only available for Pr. 190 to Pr. 194,
26
Setting range
Initial value
4
0 to 9,
5
12 to 20,
22 to 28, 31, 32,
37, 41 to 48,
6
50 to 53,
57 to 59, 62,
64 to 69, 72 to 74,
24
76 to 80, 85,
87 to 89, 92 to 96,
25
*4
9999
62
0 to 8, 10 to 20,
0
22, 25 to 28,
30 to 36,
38 to 54, 56, 60,
1
61, 63, 64, 67, 68,
70, 79, 80, 84, 90
*5
to 99
, 100 to
2
108,
110 to 116, 120,
122, 125 to 128,
3
130 to 136,
138 to 154, 156,
160, 161, 163,
164, 167, 168,
4
170, 179, 180,
184, 190 to
*5
99
199
, 200 to
208, 211 to 213,
216, 300 to 308,
311 to 313, 316,
9999
9999
9999
0 to 590 Hz, 9999
1
0, 1
0
0, 1
100%
0 to 100%
75%
0 to 100%
1
0, 1, 101 to 105
9999
0 to 50%, 9999
0.5 s
0.01 to 10 s
9999
0, 9999
0
0 to 2
0
0, 1
0 to 100 s,
9999
1000 to 1100 s,
8888, 9999
1
0, 1
50%
0 to 200%
150%
0 to 200%
Parameter Name
Main circuit power OFF
254
waiting time
255
Life alarm display
Inrush current limit
256
circuit life display
Control circuit
257
capacitor life display
Main circuit capacitor
258
life display
Main circuit capacitor
259
life measuring
Power failure stop
261
selection
Subtracted frequency
262
at deceleration start
Subtraction starting
263
frequency
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power failure decelera-
266
tion time switchover
frequency
Terminal 4 input
267
selection
Monitor decimal digits
268
selection
Parameter for manufacturer setting.
269
Do not make setting.
Stop-on contact/load
torque high-speed
270
frequency control
selection
High-speed setting
271
maximum current
Middle-speed setting
272
minimum current
Current averaging
273
range
Current averaging
274
filter time constant
Stop-on contact
excitation current low-
275
speed multiplying
factor
PWM carrier frequency
276
at stop-on contact
Brake opening
278
frequency
279
Brake opening current
Brake opening current
280
detection time
Brake operation time
281
at start
Brake operation
282
frequency
Brake operation time
283
at stop
Deceleration detection
284
function selection
Setting range
Initial value
600 s
1 to 3600 s, 9999
0
(0 to 31)
100%
(0 to 100%)
100%
(0 to 100%)
100%
(0 to 100%)
0
0, 1
0
0 to 2, 21, 22
3 Hz
0 to 20 Hz
*1
0 to 590 Hz, 9999
60/50 Hz
5 s
0 to 3600 s
0 to 3600 s,
9999
9999
*1
0 to 590 Hz
60/50 Hz
0
0 to 2
9999
0, 1, 9999
0
0 to 3, 11, 13
50%
0 to 400%
0 to 400%
100%
9999
0 to 590 Hz, 9999
16
1 to 4000
9999
0 to 300%, 9999
9999
0 to 4, 9999
0 to 30 Hz
3 Hz
130%
0 to 400%
0.3 s
0 to 2 s
0.3 s
0 to 5 s
6 Hz
0 to 30 Hz
0 to 5 s
0.3 s
0
0, 1