Download Print this page

Aappendix - Mitsubishi Electric 800 Series Assembly & Installation Manuallines

Hide thumbs Also See for 800 Series:

Advertisement

A APPENDIX
A.1 Instructions for compliance with the EU Directives
The EU Directives are issued to standardize different national regulations of the EU Member States and to facilitate free movement
of the equipment, whose safety is ensured, in the EU territory.
Since 1996, compliance with the EMC Directive that is one of the EU Directives has been legally required. Since 1997, compliance
with the Low Voltage Directive, another EU Directive, has been also legally required. When a manufacturer confirms its equipment
to be compliant with the EMC Directive and the Low Voltage Directive, the manufacturer must declare the conformity and affix the
CE marking.
The authorized representative in the EU
The authorized representative in the EU is shown below.
Name: Mitsubishi Electric Europe B.V.
Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
A.1.1 EMC Directive
We declare that this inverter conforms with the EMC Directive and affix the CE marking on the inverter.
EMC Directive: 2014/30/EU
Standard(s): EN61800-3:2004+A1:2012 (Second environment / PDS Category "C3")
This inverter is not intended to be used on a low-voltage public network which supplies domestic premises. When using the
inverter in a residential area, take appropriate measures and ensure the conformity of the inverter used in the residential area.
Radio frequency interference is expected if used on such a network.
The installer shall provide a guide for installation and use, including recommended mitigation devices.
NOTES
First environment
Environment including residential buildings/facilities which are directly connected to a low voltage main supply which also
supplies residential buildings.
Directly connected means that there is no intermediate transformer between these buildings.
Second environment
Environment including all buildings/facilities which are not directly connected to a low voltage main supply which also
supplies residential buildings,
NOTES
Set the EMC filter valid and install the inverter and perform wiring according to the following instructions.
This inverter is equipped with an EMC filter. Enable the EMC filter (Class C3). (For details, refer to the FR-A870 Instruction
Manual (Hardware).)
Connect the inverter to an earthed power supply.
To make full use of the built-in EMC filter, motor cable lengths should not exceed 20 m.