Download Print this page

Mitsubishi Electric 800 Series Assembly & Installation Manuallines page 39

Hide thumbs Also See for 800 Series:

Advertisement

Parameter Name
888
Free parameter 1
889
Free parameter 2
Cumulative power
891
monitor digit shifted
times
892
Load factor
Energy saving monitor
893
reference (motor
capacity)
Control selection
during commercial
894
power-supply
operation
Power saving rate
895
reference value
896
Power unit cost
Power saving monitor
897
average time
Power saving
898
cumulative monitor
clear
Operation time rate
899
(estimated value)
CO
FM terminal
*7
calibration
(900)
C1
AM terminal
*7
calibration
(901)
C2
Terminal 2 frequency
*7
setting bias frequency
(902)
C3
Terminal 2 frequency
*7
setting bias
(902)
125
Terminal 2 frequency
*7
(903)
setting gain frequency
C4
Terminal 2 frequency
*7
(903)
setting gain
C5
Terminal 4 frequency
*7
setting bias frequency
(904)
C6
Terminal 4 frequency
*7
setting bias
(904)
126
Terminal 4 frequency
*7
setting gain frequency
(905)
C7
Terminal 4 frequency
*7
setting gain
(905)
C12
Terminal 1 bias
*7
frequency (speed)
(917)
C13
Terminal 1 bias (speed)
*7
(917)
C14
Terminal 1 gain
*7
(918)
frequency (speed)
C15
Terminal 1 gain
*7
(918)
(speed)
C16
Terminal 1 bias
*7
command (torque)
(919)
C17
Terminal 1 bias (torque)
*7
(919)
*1
Differs according to types. (FM type/CA type)
*7
The parameter number in parentheses is the one for use with the LCD operation panel and the parameter unit.
Setting range
Initial value
9999
0 to 9999
9999
0 to 9999
9999
0 to 4, 9999
100%
30 to 150%
Inverter
rated
0 to 3600 kW
capacity
0
0 to 3
9999
0, 1, 9999
0 to 500, 9999
9999
9999
0 to 1000 h, 9999
9999
0, 1, 10, 9999
0 to 100%,
9999
9999
0 to 590 Hz
0 Hz
0%
0 to 300%
*1
0 to 590 Hz
60/50 Hz
100%
0 to 300%
0 Hz
0 to 590 Hz
20%
0 to 300%
*1
0 to 590 Hz
60/50 Hz
100%
0 to 300%
0 to 590 Hz
0 Hz
0%
0 to 300%
*1
0 to 590 Hz
60/50 Hz
100%
0 to 300%
0%
0 to 400%
0%
0 to 300%
Parameter Name
C18
Terminal 1 gain
*7
command (torque)
(920)
C19
Terminal 1 gain
*7
(torque)
(920)
C8
Current output bias
*7
signal
(930)
C9
Current output bias
*7
(930)
current
C10
Current output gain
*7
(931)
signal
C11
Current output gain
*7
current
(931)
C38
Terminal 4 bias
*7
command (torque)
(932)
C39
Terminal 4 bias
*7
(torque)
(932)
C40
Terminal 4 gain
*7
command (torque)
(933)
C41
Terminal 4 gain
*7
(torque)
(933)
C42
PID display bias
*7
coefficient
(934)
C43
PID display bias
*7
analog value
(934)
C44
PID display gain
*7
coefficient
(935)
C45
PID display gain
*7
analog value
(935)
Parameter copy alarm
989
release
990
PU buzzer control
PU contrast
991
adjustment
Operation panel
992
setting dial push
monitor selection
Droop break point
994
gain
Droop break point
995
torque
997
Fault initiation
Automatic parameter
999
setting
Simple
Simple
Simple
Direct setting
1000
selection
1003
Notch filter frequency
1004
Notch filter depth
1005
Notch filter width
1006
Clock (year)
BASIC OPERATION
Setting range
Initial value
150%
0 to 400%
0 to 300%
100%
*1
0 to 100%
—/0%
*1
0 to 100%
—/0%
*1
0 to 100%
—/100%
*1
0 to 100%
—/100%
0%
0 to 400%
20%
0 to 300%
150%
0 to 400%
100%
0 to 300%
9999
0 to 500.00, 9999
20%
0 to 300.0%
9999
0 to 500.00, 9999
100%
0 to 300.0%
100
100
1
0, 1
58
0 to 63
0 to 3, 5 to 14, 17
to 20, 22 to 36, 38
to 45, 50 to 57,
0
61, 62, 64, 67, 71
to 75, 87 to 98,
100
9999
0.1 to 100%, 9999
100%
0.1 to 100%
9999
0 to 255, 9999
1, 2, 10 to 13, 20,
9999
21, 9999
0
0 to 2
0, 8 to 1250 Hz
0
0
0 to 3
0
0 to 3
2000
2000 to 2099
33

Advertisement

loading

This manual is also suitable for:

Fr-a800-eFr-a870-02300-eFr-a870-02860-e