Programmer's Guide, cont'd
Command/response table for SIS commands (continued)
Command
Audio output volume
N The table below defines the value of each audio volume step.
dB of
value
X16
attenuation
00
76
01
63
02
62
03
61
04
60
05
59
06
58
07
57
08
56
09
55
10
54
11
53
12
52
13
51
14
50
15
49
16
48
17
47
18
46
19
45
20
44
21
43
22
42
Set the audio volume to a
specific value
Example:
Increment volume
Example:
Decrement volume
Read output volume
X1%
N
= Local audio output number
X1^
= Volume adjustment range
4-14
MTPX Plus Twisted Pair Matrix Switchers • Programmer's Guide
ASCII command
(host to switcher)
Output
dB of
value
X16
volume
attenuation
0%
5.5%
23
41
7%
24
40
8.5%
25
39
10%
26
38
11.5%
27
37
13%
28
36
14.5%
29
35
16%
30
34
31
33
17.5%
19%
32
32
20.5%
33
31
22%
34
30
35
29
23.5%
25%
36
28
26.5%
37
27
28%
38
26
39
29.5%
25
31%
40
24
32.5%
41
23
34%
42
22
43
35.5%
21
37%
44
20
X1%
X1^
*
V
1*50v
X1%
+V
1+V
X1%
-V
X1%
V
1 – 4 (matrix sizes 1616 and smaller)
1 – 8 (matrix sizes 1632 and larger)
0 – 64 (1 dB/step except for 0-to-1, which is 22 dB)
Response
Additional
description
(switcher to host)
Output
value
X16
volume
38.5%
45
40%
46
41.5%
47
43%
48
44.5%
49
46%
50
47.5%
51
49%
52
50.5%
53
52%
54
53.5%
55
55%
56
57
56.5%
58%
58
59.5%
59
61%
60
61
62.5%
64%
62
65.5%
63
67%
64
68.5%
70%
X1%
X1^]
Out
•Vol
]
Set output 1 volume to 79%.
Out01•Vol50
X1%
X1^]
Increment volume by 1 step.
Out
•Vol
]
Out01•Vol51
X1%
X1^]
Decrease volume by 1 step.
Out
•Vol
X1^]
dB of
Output
attenuation
volume
19
71.5%
18
73%
17
74.5%
16
76%
15
77.5%
14
79%
13
80.5%
12
82%
11
83.5%
10
85%
9
86.5%
8
88%
7
89.5%
6
91%
5
92.5%
4
94%
3
95.5%
2
97%
1
98.5%
0
100%