Site Preparation
Electrical Requirements
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
The electrical outlet must be positioned with the ground-
ing prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
ELECTRICAL SUPPLY LOCATION
18" Model
24" Model
30" Model
LEFT SIDE
OF OPENING
1
4
/
"
A
2
(114)
1
4
/
"
4
(108)
FLOOR
1
1
/
/
"
"
4
4
(6)
(6)
Electrical supply location
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
A
6"
(152)
9 1/2"
(241)
12 1/2"
(318)
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded.
WARNING
Do not locate multiple portable socket-outlets,
power strip, or portable power supplies at the rear of
the appliance.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
subzero.com | 5