Electrical Requirements - Sub-Zero 424 Installation Manual

Hide thumbs Also See for 424:
Table of Contents

Advertisement

Models 424 and 424FS Installation

Electrical Requirements

For models 424 and 424FS, the electrical supply should
be located within the shaded area shown in the illustra-
tion. Follow the National Electrical Code and local codes
and ordinances when installing the receptacle. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and
may cause interruption of operation.
IMPORTANT NOTE: For model 424, the electrical outlet
must be placed so the grounding prong is to the right of
the thinner blades. The outlet must be flush with the back
wall.
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity and is
properly grounded.
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance. Do not
remove the power cord ground prong.
Electrical Requirements
Power Supply
Circuit Breaker
Receptacle
2"
(51)
1
15
/
"
2
(394)
3"
(76)
FRONT VIEW
Location of electrical supply.
6
115 V AC, 60 Hz
15 amp
3-prong grounding-type