Electrical Requirements - Sub-Zero DEU1550B/L Installation Manual

Undercounter refrigeration
Hide thumbs Also See for DEU1550B/L:
Table of Contents

Advertisement

Available languages

Available languages

Site Preparation

Electrical Requirements

Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration below. A separate circuit
servicing only this appliance is required.
IMPORTANT NOTE: For indoor models, a ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause
interruption of operation.
For the outdoor model, a ground fault circuit interrupter
(GFCI) is required to reduce the risk of electrical shock.
The electrical outlet must be positioned with the ground-
ing prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
OPENING
5"
2"
(127)
(51)
4"
(102)
FLOOR
Electrical supply location
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded.
WARNING
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly quali-
fied persons in order to avoid a hazard.
WARNING
Do not locate multiple portable socket-outlets,
power strip, or portable power supplies at the rear of
the appliance.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
subzero.com | 5