INSTALLATION DIAGRAM

*
**
*
*
Power up the switching units D4L-G+/POE using FA-G+ power supply (18
Vdc).
The D4L-G+/POE can be locally powered, by connecting the power supply to the "+" and "-" terminals. Set the jumper at
D4L-G+/POE in "Local" setting position.
When setting the jumper as "Riser", the power is supplied through the IN terminal at D4L-G+/POE. In that case the IN terminal
should be linked to OUT terminal from the precedent switching unit D4L-G+/POE.
**
The maximum distance between switching unit D4L-G+/POE and a device is 70 m.
The maximum number of devices that can be connected to FA-G+ is 8.
For more connection topologies see the annex "Schematics".