Installation Diagram; Connection To (1 Apartment); Connection To (2 Apartments) - golmar AS-220S Instruction Manual

Hide thumbs Also See for AS-220S:
Table of Contents

Advertisement

INSTALLATION DIAGRAM

C
onnection to (1 apartment)
T-772VD
JP2
_ _
P+ P-
+
(1)
Call push button:
Call to apartment 1.
Call to apartment 1.
*
IMPORTANT: Configure the JP2 jumper for one or two apartments (see page 33 for the door panel and page 37 for the telephone).
C
onnection to (2 apartments).
T-772VD
JP2
_ _
P+ P-
+
(1)
Call push button:
1
2
Call to apartment 1.
1
2
Call to apartment 2.
*
IMPORTANT: Configure the JP2 jumper for one or two apartments (see page 33 for the door panel and page 37 for the telephone).
.
Apartment 1
T-772VD
JP2
_ _
P+ P-
+
JP2
C NO
12Vc.c.
Apartment 2
T-772VD
JP2
_ _
P+ P-
+
JP2
C NO
12Vc.c.
T-772VD
JP2
JP2
_ _
P+ P-
+
P+ P-
(1)
PES-220
CV CV
P-
P+
Apartment 1
T-772VD
JP2
JP2
_ _
P+ P-
+
P+ P-
(1)
PES-220
1
2
CV CV
P-
P+
T-772VD
FA-33
SEC PRI
_ _
_ _
~
+
+
230Vc.a.
T-772VD
FA-33
SEC PRI
_ _
_ _
~
+
+
230Vc.a.
39
~
~