Check the tension value in the app.
For a correctly tensioned Timing Belt on the X1 axis, the measured value should be between 90 and 97 Hz
at the location shown in Fig. 43.
Fig. 43 Measured value of toothed belt tension
8. Measuring the timing belt tension on the X2 axis (Fig. 38):
Place the phone with the microphone facing the toothed belt side at the third black mounting hole of the
linear guide counting from the right side of the printer (Fig. 44).
Fig. 44 Measurement location of timing belt tension on the X2 axis
Select the start button in the app.
Make the timing belt vibrate by vigorously jerking it like a guitar string until the measuring fields in the
app light up green.
Check the tension value in the app.
3DGence INDUSTRY F340 - maintenance activities | version 04.2019