User Parameter List - Yamato DP-5601 Operation Manual

Table of Contents

Advertisement

User Parameter List

NO. ITEM
001
DISPLAY BRILLIANCE
002
DIMMER TIMER
003
NOT USED
004
NOT USED
005
NOT USED
006
MANUAL TOTALIZATION
007
NON-ADDITION
008
PRINTER, JPS-508
009
PRINT ITEM
010
PRINT TIME AND DATE
011
FEED AFTER PRINT
012
FEED AFTER TOTAL PRINT
031
NOT USED
033
NOT USED
035
"SEnd" DISPLAY TIME
PRINTER TPS-503W
053
LCD CONTRAST
054
NOT USED
055
NOT USED
056
NOT USED
058
AUTO POWER ON
059
AUTO CALL AT POWER ON
060
AUTO ADDITION MODE AT
POWER ON
061
AUTO CANCEL OF TARE
062
ITEMIZED TOTAL & GRAND
TOTAL
063
GROSS CALCULATION
064
NOT USED
065
NOT USED
066
ONE-TIME ADDITION
067
DELAY TIME FOR
AUTOMATIC ADDITION
068
ZERO ADDITION
VALUE
DEFAULT FUNCTION
000:
002
VERY DIM
001:
DIM
002:
STANDARD
003:
BRIGHT
004:
VERY BRIGHT
000:
010
DIMMER OFF
001-006:
PERIOD BEFORE RETURN TO BRILLIANCE 00
000
DO NOT CHANGE
000
DO NOT CHANGE
000
DO NOT CHANGE
000:
000
[+], [-] KEYS INVALID IN AUTOMATIC MODE
001:
[+], [-] KEYS VALID IN AUTOMATIC MODE
000:
000
TOTALIZE
001:
NO TOTALIZATION, DATA OUTPUT ONLY
([TOTAL] KEY DOES NOT WORK.)
000:
001
PRINTER JPS-508 NOT USED
001:
NET WEIGHT PRINTED
002:
GROSS, TARE AND NET WEIGHT PRINTED
003:
DO NOT SET
004:
OVER AND SHORT PRINTED (TO BE SET #68=1)
000:
003
CODE NO. AND MEASUREMENT TIMES NOT PRINTED
001:
CODE NO. PRINTED
002:
MEASUREMENT TIMES PRINTED EVERY WEIGHING
003:
CODE NO. & MEASUREMENT TIMES PRINTED
004-007:
DO NOT SET
000:
002
TIME AND DATE NOT PRINTED
001:
TIME PRINTED EVERY WEIGHING
002:
DATE PRINTED AT TOTALIZATION
003:
DATE PRINTED AT TOTALIZATION AND TIME PRINTED
EVERY WEIGHING
004:
DATE PRINTED EVERY WEIGHING
005:
TIME AND DATE PRINTED EVERY WEIGHING
000:
000
NO PAPER FEED
001-020:
FEED SPECIFIED LINES AFTER WEIGHING
000:
006
NO PAPER FEED AFTER TOTAL PRINT
001-20:
FEED SPECIFIED LINES AFTER TOTAL PRINT
000
DO NOT CHANGE
000
DO NOT CHANGE
000:
001
NO "SEnd" DISPLAYED AT ADDITION
001-008:
"SEnd" DISPLAYED FOR SPECIFIED SECONDS AT ADDITION
125
DO NOT CHANGE
000
DO NOT CHANGE
005
DO NOT CHANGE
000
DO NOT CHANGE
000:
000
NOT POWER ON AT PLUG IN
001:
POWER ON AT PLUG IN
000:
000
NO FUNCTION
001:
CALL #1 DISPLAYED AUTOMATICALLY AT POWER ON
000:
000
MANUAL ADDITION MODE AT POWER ON
001:
AUTO ADDITION MODE AT POWER ON
000:
000
NO FUNCTION
001:
TARE CANCELED WHEN G/W IS LESS THAN 4 DIVISIONS
002-003:
NOT USED
000:
000
ITEMIZED TOTAL NOT AVAILABLE
001:
ITEMIZED TOTAL AVAILABLE (AT #59=001)
002:
GRAND TOTAL AVAILABLE
003:
GRAND TOTAL, MAX, MIN, AVERAGE AND PRINT RANGE
ARE EFFECTIVE
000:
000
INITIAL COUNTS CONVERTED INTO WEIGHT
001:
CALCULATED BY NET+TARE (VALID AT #194=0)
000
DO NOT CHANGE
000
DO NOT CHANGE
000:
001
MANUAL ADDITION EVEN FOR THE SAME ITEM IS
POSSIBLE AT ANY TIME THE WEIGHT IS STABLE
001:
ONE-TIME MANUAL ADDITION IS POSSIBLE WHEN IT IS
STABLE AFTER PASSING THE VICINITY OF THE ZERO POINT
002:
REAL TIME ADDITION IRRESPECTIVE OF STABILITY
000:
000
ADDITION WITH NO DELAY TIME
001-050:
ADDITION AFTER THE SPECIFIED TIME
- THE SETTING VALUE x 100ms
000:
000
NO ADDITION WITH THE INDICATION BEING 0
21
REMARKS
Adjust the
brilliance of the
display.
Valid only
connection to
Printer JPS-
508.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edi-561