7 Technical Parameters

Technical Data
Input
Max.Input Power (W)
Max.Input Voltage (V)
MPPT Operating Voltage
Range (V)
MPPT Voltage Range at
Nominal Power (V)
Start-up Voltage (V)
Nominal Input Voltage
(V)
Max. Input Current per
MPPT (A)
Max. Short Circuit
Current per MPPT (A)
Number of MPPT
Number of Strings per
MPPT
Output
Nominal Output Power
(W)
Nominal Output
Apparent Power (VA)
Max. AC Active Power (W)
Max. AC Apparent Power
(VA)
Nominal Power at 40℃
(W)
Max Power at 40℃
(including AC overload)
(W)
Nominal Output Voltage
(V)
Nominal AC Grid
Frequency (Hz)
Max. Output Current (A)
Nominal Output Current
(A)
Output Power Factor
Max. Total Harmonic
Distortion
Efficiency
Max. Efficiency
European Efficiency
Protection
Residual Current
Monitoring Unit
GW2900D-NS
GW3000D-NS
4000*
3900*
535
600
80-435
80~550
N/A
150~550
80
80
230
360
12.5 / 12.5
11/11
15.6 / 15.6
13.8/13.8
2
2
1
1
2900
3000
*1
2900
3000
2900
3000
2900
3000
2900
3000
2900
3000
127
220/230
60
50/60
22.9
13.6
22.9
13.6/13
~1 (Adjustable from 0.8 leading to 0.8 lagging)
<3%
<3%
96.0%
97.8%
95.6%
97.5%
GW3600D-NS
GW4200D-NS
4680*
5460*
600
600
80~550
80~550
180~550
210~550
80
80
360
360
11/11
11/11
13.8/13.8
13.8/13.8
2
2
1
1
3680
4200
*1
3680
4200
3680
4200
3680
4200
3600
4200
3600
4200
220/230
220/230
50/60
50/60
16
19
16/15.6
19/18.2
<3%
<3%
97.8%
97.8%
97.5%
97.5%
Integrated
29
GW5000D-NS
GW6000D-NS
6500*
600
80~550
80~550
240~550
280~550
80
360
11/11
13.8/13.8
13.8/13.8
2
1
5000
*1
*1*2
5000*3
5000
5000
5000
5000
220/230
220/230
50/60
22.8
22.8/21.7
27.3/26.1
<3%
97.8%
97.5%
7200
600
80
360
11/11
2
1
6000
*1
6000
6000
6000
6000
6000
50/60
27.3
<3%
97.8%
97.5%

Advertisement