Panasonic AJ-SD93P/E Service Manual page 62

Digital video cassette recorder
Table of Contents

Advertisement

Item
Set value
SUPER
No.
No.
DISP.
P61
0
EQ STB
Q61
1
R61
P62
0
AEQ MODE
Q62
1
R62
P63
0
AEQ HOLD
Q63
1
R63
P64
0
FLT MODE
Q64
1
R64
P65
0
PLL MONI
Q65
1
R65
P66
1
MONI KINDSEL
Q66
2
R66
3
P67
0
MONI CHSEL
Q67
1
R67
2
3
4
P68
0
ECC MODE
Q68
1
R68
2
P69
0
CONCEAL MOD
Q69
1
R69
P70
0
ERROR MODE
Q70
1
R70
P71
0
TRACKING MOD
Q71
1
P72
-128
TRACKING VAL
Q72
|
R72
0
|
127
P73
ATF HEAD
0
Q73
1
R73
Setting contents and
SUPER
outline function explanation
DISP.
OFF
ON/OFF setting for the automatic standby detection function
ON
Automatic standby detection function:
When the playback envelope is not detected for several
seconds, the mode automatically shifts to standby mode (the
mode where playback processing is stopped and the VCO center
frequency is adjusted automatically).
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
OFF
Setting of the Adaptive EQ function of the adaptive equalization filter
ON
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
OFF
ON/OFF setting for the function for temporary holding of adaptive
ON
equalization control during the transitional period when the relative
speed changes.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
OFF
ON/OFF setting for the fault detection function
ON
Fault detection function:
When the adaptive filter or the PLL drops into a divergent state
at the time of mode switching like search etc., and a status is
detected where no normal signal can be detected over a period
of 5 tracks or more, this function pulls the status of the adaptive
filter or the PLL to the initial status.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
OFF
ON/OFF setting for PLL frequency monitor control
ON
Frequency monitor control:
When a status is detected where the playback clock frequency at
the time of mode switching during palyback is outside the
permissible range set by MONI LIM PB1 for the specified time or
longer, this function automatically pulls the frequency back to the
reference frequency corresponding to the relative speed.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
ENV
Selection of monitor signal
EYEE
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
EYEO
ADJUST.
OFF
Selection of monitor channel(Head)
PBL
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
PBR
ADJUST.
RPL
RPR
ALL ON
Setting of error correction control
OT OFF
0: Error correction for INNER and OUTER.
AL OFF
1: Error correction only for INNER, but not for OUTER.
2: No error correction for INNER and OUTER.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
ON
Setting of error revision control
OFF
0: Error revision is performed.
1: Error revision is not performed.
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
FAST
Setting of the error sampling time
SLOW
0: FAST mode
1: SLOW mode
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
ATF
Tracking mode setting
CTL
0: ATF tracking
1: CTL tracking
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
ADJUST.
-128
Offset value setting for CTL tracking
|
• Effective only at the time of TRACKING MOD = CTL.
0
• The setting is held until exit from 50M ADJUST, 25M ADJUST DV
|
ADJUST.
127
PB
Head selection for ATF tracking
RP
0: PB head
1: RP head
INF-49
BACK
Remarks
-UP
Factory use only
No
No
Use for electrical adjustment
No
Factory use only
No
Factory use only
No
Factory use only
No
Use for electrical adjustment
No
Use for electrical adjustment
No
No
No
No
No
No