Panasonic AJ-SD93P/E Service Manual page 53

Digital video cassette recorder
Table of Contents

Advertisement

PB ADJUST (DVCPRO 50M ADJUST, DVCPRO 25M ADJUST sub-screen)
Item
Set value
SUPER
No.
No.
DISP.
P01
-128
PHS L1
Q01
|
-20
|
127
P02
-128
PHS L2
Q02
|
-20
|
127
P03
-128
MAG L1
Q03
|
20
|
127
P04
-128
MAG L2
Q04
|
20
|
127
P05
-128
PHS R1
Q05
|
-20
|
127
P06
-128
PHS R2
Q06
|
-20
|
127
P07
-128
MAG R1
Q07
|
20
|
127
P08
-128
MAG R2
Q08
|
20
|
127
P09
0
ENV L1
Q09
|
255
P10
0
ENV L2
Q10
|
255
P11
0
ENV R1
Q11
|
255
P12
0
ENV R2
Q12
|
255
0
P13
AGC SPD
Q13
|
3
P14
AEQ SPD
0
Q14
1
2
3
P15
HLD SEN
0
Q15
1
2
3
SUPER
outline function explanation
DISP.
-128
Adjustment of the L1 head playback phase
|
-20
|
127
-128
Adjustment of the L2 head playback phase
|
-20
|
127
-128
Adjustment of the L1 head playback amplitude
|
20
|
127
-128
Adjustment of the L2 head playback amplitude
|
20
|
127
-128
Adjustment of the R1 head playback phase
|
-20
|
127
-128
Adjustment of the R2 head playback phase
|
-20
|
127
-128
Adjustment of the R1 head playback amplitude
|
20
|
127
-128
Adjustment of the R2 head playback amplitude
|
20
|
127
0
Playback signal envelope level read-out value averaged for each
|
track of each head
255
ENV L1: L1 head
ENV L2: L2 head
0
Averaging is performed at 8 points in the track, and the newest track
|
value for which averaging has been completed at the time when
255
read-out is started will be read out.
• Read-out is possible only at the time of PLAY and REC.
0
|
255
0
|
255
0
Setting of the AGC response speed
|
3
0
The control response speed for the adaptive equalization filter is set
1
in four levels.
2
The sensitivity is highest with 0 and lowest with 3.
3
0
The detection sensitivity for detection of changes in the relative
1
speed is set in four levels.
2
The sensitivity is highest with 0 and lowest with 3.
3
Setting contents and
INF-40
BACK
Remarks
-UP
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Use for electrical adjustment
Yes
Factory use only
Yes
Factory use only
Yes
Factory use only
Factory use only
Yes
Factory use only
Yes
Do not change any setting
Yes
Factory use only
Do not change any setting
Yes
Factory use only
Do not change any setting