Item
Set value
SUPER
No.
No.
DISP.
P16
FLT SEN
0
Q16
1
2
3
P17
PLLREV
0
Q17
1
P18
PLL PHS
0
Q18
|
9
|
31
P19
REV LEV
0
Q19
1
2
3
P20
0
PLL FRQ
Q20
|
8
|
31
P21
0
MONI LIM W
Q21
|
28
|
127
P22
0
MONI LIM N
Q22
|
28
|
127
P23
0
TH EYE
Q23
|
110
|
255
P24
TH ULK
0
Q24
|
98
|
255
P25
TH ENV
0
Q25
|
16
|
255
P26
0
PLL LIM
Q26
|
7
P27
0
VCO L
Q27
|
512
|
1023
P28
0
VCO R
Q28
|
512
|
1023
Setting contents and
SUPER
outline function explanation
DISP.
0
The detection sensitivity for the fault detection function is set in four
1
levels.
2
A fault status is detected when a status where a normal signal can
3
not be detected consecutively for 5 tracks over the following track
values.
0: 1/2
1: 3/4
2: 7/8
3: 15/16
SLOW
The compensation speed in PLL frequency compensation mode is
FAST
set in two levels
0
In the PLL response speed setting, mainly the phase pull-in speed is
|
controlled. The response speed becomes faster with larger values.
9
|
31
0
The strength of the frequency pull-in operation of the PLL phase
1
comparison characteristic expansion function is controlled in four
2
levels. The action is weakest with 0 and strongest with 3.
3
When the data acquisition ratio at the time of special playback is bad,
it can be improved by controlling this parameter.
0
The setting of the PLL response speed controls mainly the frequency
|
pull-in speed. The response becomes faster with larger values.
8
|
31
0
Setting of the frequency offset tolerance value for PLL frequency
|
monitor control
28
The actual tolerance range in regard to the reference frequency is
|
(set value)/10.24%.
127
0
Setting of the frequency offset tolerance value for PLL frequency
|
monitor control
28
The actual tolerance range in regard to the reference frequency is
|
(set value)/10.24%.
127
0
Setting of the threshold value for judging the signal quality after
|
equalization
110
The judgment result for the signal quality is used for adaptive
|
equalization, PLL, fault detection function, and other control.
255
0
Setting of the threshold value for judging the signal quality after
|
equalization
98
The judgment result for the signal quality is used for adaptive
|
equalization, PLL, fault detection function, and other control.
255
0
Setting of the threshold value for the envelope detection signal
|
The envelope detection signal is used for adaptive equalization filter,
16
PLL, and AGC hold control.
|
255
0
In the PLL response speed setting, mainly the phase pull-in speed is
|
controlled.
7
0
Setting of the initial value of the output voltage adjusting the VCO
|
center frequency
512
Adjustment is performed automatically in standby mode, but the time
|
required for automatic adjustment can be reduced by setting this
1023
value in advance to a suitable value.
0
The automatically adjusted value is read out and set.
|
• Read-out is possible only at the time of EJECT, STANDBY-OFF.
512
|
1023
INF-41
BACK
Remarks
-UP
Yes
Factory use only
Do not change any setting
Yes
Factory use only
Do not change any setting
Yes
Factory use only
Do not change any setting
Factory use only
Yes
Do not change any setting
Yes
Factory use only
Do not change any setting
Yes
Factory use only
Do not change any setting
Yes
Factory use only
Do not change any setting
Yes
Factory use only
Do not change any setting
Yes
Factory use only
Do not change any setting
Yes
Factory use only
Do not change any setting
Factory use only
Yes
Do not change any setting
Yes
Use for electrical adjustment