EVO INVERTER/CHARGER |
A
B
To Remote Start/Stop
C
Terminals on the
Generator
14
Optional
+
Generator Auto
-
Start/Stop Control
Module
Optional
Remote Control
EVO-RC
Ground
Terminal (5)
EVO INVERTER
CHARGER
-
Battery
External
Charge
Controller
-
PV

Solar Panel(s)

DC SIDE OF EVO
Battery Positive
1.
2.
Battery Negative
3.
External Charger Positive
4.
External Charger Negative
5.
Grounding Terminal
6.
RF-45 Jack for Temperature Sensor
7.
RJ-45 Jack for Optional Remote Control EVO-RC
14.
Status Relay Terminals for initiating automatic generator start/stop
Solar Panel(s)
CAUTIONS!
!
1. When both the Grid and Generator are connected to the EVO
(i) The generator chassis / frame is grounded to the Earth Ground through Ground Rod of the Grid Electrical Panel and
(ii) The Neutral conductor of the generator is NOT bonded to the chassis / frame of the generator. Please refer to Section 3.14.2.1 for details.
2. If only Generator is connected (no Grid connection), the Neutral of the Generator SHOULD BE BONDED to its metal frame. Please refer
to Section 3.14.2.2
!
ATTENTION!
1. Lorsque le réseau et le générateur sont connectés simultanément à l'EVO, comme indiqué sur la gure 3.14, veuillez vous assurer que :
(i) Le générateur / châssis châssis est relié à la masse de la Terre par l'intermédiaire de tige de mise à la terre du panneau électrique et grille
(ii) le conducteur neutre de la génératrice n'est pas collé sur le châssis / cadre de la génératrice. Veuillez vous reporter à la section 3.14.2.1 pour
plus de détails.
2. Si seul le générateur est connecté (pas de connexion au réseau), le neutre du générateur DOIT ÊTRE LIÉ à son cadre métallique.
Veuillez vous référer à la section 3.14.2.2
4 | SAMLEX AMERICA INC.
NO - Normally Open Contact
Common
NC - Normally Closed Contact
BATTERY
A
TEMPERATURE
SENSOR MODEL
B
EVO-BCTS
C
Fuse
4
3
14
1
6
7
2
5
FRONT
(See Fig 2.1)
AC SIDE
(See Fig 2.3)
Minimum Wire
+
Battery
Size AWG #6
+
PV
Status Relay
To optional
NO
Generator Auto
Common
Start/Stop
NC
Module
Fig 1 Typical Shore Based Installation
Quick Start Guide
BATTERY SIDE FUSE (Within 7" of Positive Post)
-
+
LEAD ACID
BATTERY BANK
12
10
8
6
4
9
5
11
7
G
GENERATOR
(See Caution!)
PANEL
L
N
E
GE
Ground Rod embedded in earth.
AC SIDE OF EVO
4.
GRID LINE
5.
GRID GND
6.
GRID NEUTRAL
7.
GEN LINE
8.
GEN GND
9.
GEN NEUTRAL
10.
OUTPUT LINE
11.
OUTPUT GND
12.
OUTPUT NEUTRAL
simultaneously as shown in this Fig 3.14, please ensure that:
TM
Pos (+)
Bus
G-B
LINE
N
To
Loads
N-B
G-B
GEC
GRID ELECTRICAL
PANEL (120/240VAC),
SPLIT PANEL
N-B
A
B
G-B
SBJ
GEC
GEC
OTHER
Circuit breaker
A
120 VAC Leg A
B
120 VAC Leg B
(Legs A&B are split phases)
N-B
Neutral Bus Bar
SBJ
System Bonding Jumper
G-B
Grounded Bus Bar
GE
Grounding Electrode (Ground Rod)
GEC
Grounding Electrode Conductor
E
Earth Connector on generator
(bonded to frame/chassis of the generator)
N
Neutral terminal of generator output
L
Line terminal of generator output
G
Grounding terminal of generator output
DC ELECTRICAL
PANEL
Neg (-) Bus
ELECTRICAL
SUB- PANEL
FOR EVO
(
CAUTION!
Use 120 VAC
Single Phase
Panel and NOT
120/240VA
Split Phase
Panel)
SERVICE
PANEL
+
-