Alpha-InnoTec HT 6Split Installation And Operating Manual page 50

Indoor unit cooperating with air heat pumps
Hide thumbs Also See for HT 6Split:
Table of Contents

Advertisement

Factory settings: auto
Auto
In this operating mode, the heat pump automatically
selects what functions are available to select.
Manual
In this operating mode you can select what functions
will be available to select. It is not possible to deselect
"compressor" in manual mode.
Add. heat only
In this operating mode the compressor is not active,
additional heat only is used.
IMPORTANT
Selecting the "add. heat only" mode will block the com-
pressor and result in higher costs for running the system.
Menu 4.4 - Date and time
Set time and date, display mode and time zone in this
menu.
Menu 4.6 - Language
In this menu, choose the language that you want the
information to be displayed in.
Menu 4.7 - Holiday sched.
To reduce energy consumption during a holiday you
can schedule a reduction in heating and hot water
temperature. Cooling operation, ventilation, pool and
solar collector cooling can also be scheduled if the
functions are connected.
If a room sensor is installed and activated, the de-
sired room temperature (°C) is set during the given
time period. This setting applies to all climate systems
with room sensors.
If a room sensor is not activated, set the desired off-
set of the heating curve. One step is usually enough
to change the room temperature by one degree, but
in some cases several steps may be required. This
setting applies to all climate systems without room
sensors.
Holiday scheduling starts at 00:00 on the start date
and stops at 23:59 on the finish date.
Chapter 9 |
50
Control
CAUTION
If you choose to stop hot water production for a holi-
day, "periodic increase" (preventing bacterial growth)
will be blocked during this time. "periodic heat in-
crease" will start up in conjunction with the vacation
setting ending.
Menu 4.9 - Advanced
In this menu, you can configure the advanced oper-
ational functions of the controller for HT 6Split / HT
12Split. For more information select " ? ".
Menu 4.9.1 - Operating priority
Choose here how long the heat pump should work with
each requirement if there are two or more requirements
at the same time (e.g. for heating and hot water). If there
is only one requirement, the heat pump only works with
that requirement.
The indicator marks where in the cycle the heat pump
is. If 0 minutes is selected it means that requirement is
not prioritised, and will only be activated when there is
no other requirement. For more information select " ? ".
Menu 4.9.2 - Auto mode setting
When the operating mode is set to "auto", the heat
pump selects when to start and stop the additional
heat and heat production, dependent on the average
outdoor temperature.
Select the average outdoor temperatures in this menu.
You can also set the time (filtering time) at which the
average temperature is calculated. If you select 0, the
current outdoor temperature is used. For more infor-
mation, select " ? ".