SQ 05.2
SQ 14.2/SQR 05.2
AC 01.2 Non-Intrusive
5.3.1.
Overview on coupling variants
Design
Application
5.3.2.
Mount actuator (with coupling)
Assembly steps
SQR 14.2 Control unit: electronic (MWG)
Figure 11: Valve attachment via coupling
[1]
Bore with keyway
[2]
Square bore
[3]
Bore with two-flats
For valve attachments according to EN ISO 5211
For rotating, non-rising valve stem
Unbored couplings or couplings with pilot bore must be machined to match the valve
shaft prior to mounting the actuator to the valve (e.g. with bore and keyway, two-flat
or square bore).
Assemble valve and actuator in the same end position. As standard, the actu-
ator is supplied in end position CLOSED.
Recommended mounting position for butterfly valves: End position CLOSED.
Recommended mounting position for ball valves: End position OPEN.
1.
If required, move actuator in same end position as valve using the handwheel.
2.
Clean mounting faces, thoroughly degrease uncoated mounting surfaces.
3.
Apply a small quantity of grease to the valve shaft [2].
Assembly
17