  • Page 1 OWNER’S MANUAL Supercell ® Supercell Turbo ® High-Pressure Dust Collector 14 Gallon # XSK000014 # XSK414000 U.S. Patent: #8393050, #8377160, #9125535, #D917806 READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNING LABELS BEFORE USING THE DUST COLLECTOR. Appearance may vary slightly Rev: B 20221128LL...
  • Page 3: Table Of Contents

    Table of Contents System Start-Up Information Supercell/Supercell Turbo System Specifications System Dimensions System Contents Assembly Instructions Maintenance Troubleshooting F.A.Q. Recommended Accessories Warranty Information oneida-air.com...
  • Page 4: System Start-Up Information

    Consult this owner’s manual or reach out for recommended accessories. 13. ENSURE enough air volume is at the suction point to capture all the particulate generated. Oneida Air Systems, Inc.
  • Page 5 System Start-Up Information (Continued) 14. NEVER make modifications without prior approval from Oneida Air Systems. Modifying the dust collector or using it differently than intended will void the warranty and may result in malfunction or mechanical failure that leads to serious personal injury or death! 15.
  • Page 6 Oneida Air Systems assumes no responsibility or liability for the suitability of any fire and/ or explosion mitigation strategy, or any items incorporated into a collector as part of an owner/operators hazard mitigation strategy.
  • Page 7 System Start-Up Information (Continued) 12. ALWAYS check your dust bin for smoldering materials before leaving the shop. 13. NEVER introduce sparks or sources of ignition into the dust collector. Sparks can be generated in several ways: a. High speed sanders, abrasive planers, saws, and edgers may strike foreign material and create a red-hot metal fragment.
  • Page 8: Supercell/Supercell Turbo System Specifications

    5" O.D. Overall Height 14 Gallon: 61" Overall Weight 14 Gallon: 76 lbs The Supercell requires a 20 Amp The Supercell Turbo requires that Licensed Electrician outlet receptacle to be installed by a it be installed to a 30 Amp breaker R E QU I RE D licensed electrician.
  • Page 9: System Dimensions

    System Dimensions Nominal dimensions shown. Dimensions subject to slight variations in manufacturing. Mounting dimensions allow for 13/16" clearance when removing and emptying the drum Allow for an additional 24" of clearance above the Motor Assembly to allow for its removal during filter replacement and other maintenance.
  • Page 10: System Contents

    AFR316066 Rivets G20B RLH000005 3/8” Socket SMS040001 Supercell Wall Bracket G20C RLH000004 3/8" Male Plug AHX000021 Supercell 14 Gal. Model Hardware Pack G20D RLH000002 Nylon Washer ZBT040001 Supercell Wall Bracket Template G20E RLH000003 Rubber O Ring RGF000015 15" Barrel Gasket...
  • Page 11 FINISH: NAME: 14Ga Galv THE INFORMATION CONTAINED IN THIS FPX040001 - Filter Hold Down 14ga rev 3 DRAWING IS THE SOLE PROPERTY OF Oneida Air Systems Inc. AND SHALL SIZE TOL: PART NO. FPX040001 NOT BE USED OR DISCLOSED TO...
  • Page 12: Assembly Instructions

    (G24) and adhere them to the Wall Bracket (F), lining them up with your reference line [FIG. 1e]. Note: Press each gasket piece firmly onto the FIG. 1e bracket to ensure a long-lasting, airtight seal. Oneida Air Systems, Inc.
  • Page 13 Allow for an additional 3" of clearance around the system for ease of access to the latches. FIG. 2 Identify where you will install the Supercell in your shop. It must mount to a reinforced 16" 406 mm wall (studs, concrete, etc.) and is designed to...
  • Page 14 Place washers onto each fastener and thread 1/2" 13 mm the fasteners into all four holes, leaving at least 1/2" outside of the hole to fit the Wall Bracket (F) and Rear Support Brace (G13) [FIG. 7]. FIG. 7 Oneida Air Systems, Inc.
  • Page 15 Assembly Instructions (Continued) Lift the Wall Bracket (F) up and over the fasteners so that the washer is on the inside of the bracket. Slide the Wall Bracket (F) down so that the fastener is snugly inside the smaller section of each keyhole [FIG. 8]. FIG.
  • Page 16 (E) onto the Wall Bracket (F) and align the hole patterns on all three items. Secure together using six Hex Head Bolts (G4), six Flat Washers (G5), and six Nylock Nuts (G6) [FIG. 15]. FIG. 15 Oneida Air Systems, Inc.
  • Page 17 Assembly Instructions (Continued) Secure the Rear Support Brace (G13) to the Cyclone (E) using a 2-1/2" Hex Head Bolt (G7), Flat Washer (G8), Nylon Spacer (G12), Rubber Washer (G9), and Whiz-Lock Nut (G10) as shown in [FIG. 13]. Note: Ensure that the Whiz-Lock Nuts are torqued down so that the rubber washers are firmly compressed - this will prevent air leaks.
  • Page 18 (by roughly 50%). FIG. 17 Open and slide the Ring Clamp (D) over the assembly so that it rests outside the upper flange of the Cyclone (E) [FIG. 18]. FIG. 18 Oneida Air Systems, Inc.
  • Page 19 Assembly Instructions (Continued) Using pliers, squeeze and open the Double Spring Clamp (G19) and slip it onto the shorter end of the Tubing Assembly (G18A). Then, with the clamp still open, slide the Tube Assembly (G18) onto the vent tube near the Cyclone’s (E) inlet, closing the Spring Clamp once the hose is fully seated [FIG.
  • Page 20 Note: Which hole you use will be determined by the orientation of your Motor Assembly (A). Use whichever hole is closest to ensure adequate length for the Tubing Assembly (G18) to connect to the Drum (J1). FIG. 23 Oneida Air Systems, Inc.
  • Page 21 Assembly Instructions (Continued) Connect the Dust Sentry's power adapter (I) to the small cord next to the Motor Assembly's (A) magnetic starter [FIG. 24]. The Dust Sentry's strobe light (I) should be mounted in a highly visible area using adhesive strips or the two mounting holes.
  • Page 22 (J1). Take care to ensure that the bag is fully expanded to the inside of the Drum (J1) and that the upper edge of the Liner Bag is folded out and over the lip of the Drum [FIG. 29]. FIG. 29 Oneida Air Systems, Inc.
  • Page 23 Drum should be in light contact with both Hex Head Bolts as the Drum is lifted up and latched. FIG. 31 ONLY USE VACUUM PRESSURE RATED FLEX-HOSE AND DUCT WITH THE SUPERCELL DUST COLLECTOR.  UNDER THE SYSTEM'S HIGH SUCTION, STANDARD HOSE/PIPE MAY COLLAPSE CAUSING AFFIXED TOOLS TO BE PULLED TOWARDS THE SYSTEM, POTENTIALLY CAUSING DAMAGE AND/OR INJURY.
  • Page 24: Maintenance

    Replace the motor section and re-latch the drum clamp Use a hand-held, compressed air nozzle with a pressure up around the motor section. to 90 PSI max to blast air along the filter’s exterior pleating. Oneida Air Systems, Inc.
  • Page 25 Maintenance (Continued) Emptying the Drum Cleaning out the Cyclone When first using the dust collector, check the Drum If the drum becomes overfilled and the cone is packed Window (J1) regularly to get an idea of how often it needs with dust: to be emptied.
  • Page 26: Troubleshooting

    2. Use the QR Code shown to download our instructions for the Testing and Replacement of the Motor Maintenance Kit. If you continue to experience difficulty with your dust collector, call Oneida Air Systems’ Customer Service Ÿ Department at 1-866-387-8822 or email support@oneida-air.com.
  • Page 27 5. The antenna wire can be further extended for improved reception if still necessary. Use wire strippers to expose metal on the wire and attach an additional length. If you continue to experience difficulty with your dust collector, call Oneida Air Systems’ Customer Service Ÿ...
  • Page 28: F.a.q

    How many tools can I collect from simultaneously? The Supercell and Supercell Turbo can accommodate up to three 1" to 2.5" tools at the same time or one tool with a 4" or 5" diameter port. What's the furthest length and diameter of hose that I can run? You can run up to one hundred feet of four inch flex hose.
  • Page 29: Recommended Accessories

    Supercell 4" / 2.5" Quick-Clamp Ductwork Kit #KDZ000012 • Upgrade your Supercell dust collector to connect to multiple tools simultaneously. • Includes gated connection ports for two 4" diameter and three 2.5" diameter connections. • Features modular quick-clamp duct fittings that are highly customizable for any shop.
  • Page 30 #SDD990000 • This lightweight and low profile mobile dolly fits nearly any cylindrical waste bin. • Includes hardware for securing larger drums to the dolly. • Includes five 2" non-marking caster wheels (3 non-locking, 2 locking). Oneida Air Systems, Inc.
  • Page 31: Warranty Information

    In no event shall Oneida Air Systems’ liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of New York, County of Onondaga.
  • Page 32 Regardless of where you purchased your system, if you have any questions or issues with missing / damaged parts, please call Oneida Air Systems first to let us help resolve your problem. We fully stand behind the quality of our product and place the utmost value satisfaction of our customers.