Access Control; Interfaces For Automation - EWM Microplasma 25-2 PG RC Operating Instructions Manual

Table of Contents

Advertisement

Design and function

Access control

5.6
Access control
The machine control can be locked to secure it against unauthorised or unintentional adjustment. The
access block has the following effect:
The parameters and their settings in the machine configuration menu, Expert menu and operation se-
quence can only be viewed but not changed.
Welding procedure and welding current polarity cannot be changed.
The parameters for setting the access block are configured in the machine configuration
menu > see 5.9 chapter.
Enabling access block
Assign the access code for the access block: Select parameter
999).
Enable access block: Set parameter
The access block activation is indicated by the "Access block active" signal light > see 4.3 chapter.
Disabling access block
Enter the access code for the access block: Select parameter
number code (0–999).
Disable access block: Set parameter
access block is to enter the selected number code.
5.7

Interfaces for automation

Do not carry out any unauthorised repairs or modifications!
To avoid injury and equipment damage, the unit must only be repaired or modified by
specialist, skilled persons!
The warranty becomes null and void in the event of unauthorised interference.
Appoint only skilled persons for repair work (trained service personnel)!
Damage to the machine due to improper connection!
Unsuitable control leads or incorrect connection of input and output signals can cause damage
to the machine.
Only use shielded control leads!
If the machine is to be operated with control voltages connection via suitable isolation ampli-
fiers is required!
To control the main or secondary current via control voltages, the relevant inputs must be
enabled (see specification for activation of control voltage).
48
to access block enabled
to access block disabled
WARNING
and select a number code (0–
.
and enter the previously selected
. The only way to disable the
099-007033-EW501
4.1.2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Microplasma 25-2 PG RC and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Microplasma 55-2 pg rcMicroplasma 105-2 pg rc

Table of Contents