JUKI DDL-8000A Engineer's Manual page 145

Direct-drive, high-speed, automatic thread trimmer
Hide thumbs Also See for DDL-8000A:
Table of Contents

Advertisement

⑨ Attaching the motor cable guide
Condensation solenoid cord
Cable guide
⑩ Connecting the cord
Insert the condensation solenoid pins into the optional connecter of the thread clamp solenoid, as shown
in the figure.
(Insert the black pin to No. 5 and the white pin into No. 10 of the 10-pin connector. The thread clamp
solenoid pins have already inserted into Nos. 4 and 9.)
Optional connecter
of the thread clamp
solenoid
⑪ Installing the AK cover, pulley and electrical box
Reversing the disassembly procedure, install the AK cover, pulley and electrical box.
[4] Panel setting
① Initial setting
P132 Operation starting duty of the condensation solenoid: 55
P133 Duty when the condensation solenoid operates: 10
Change the set values to the aforementioned value in order to operate the condensation solenoid without
fail.
② Setting the number of stitches
Set the number of condensation stitches at the end of sewing to 2.
P129 Number of condensation stitches at the end of sewing: 2
1) Secure the motor cable guide on the condensation
solenoid cord. Then, pass the cord from below
upward, on the far side of the motor cable guide.
Then, pull the cord toward the near side.
10
Optional connecter of the
thread clamp solenoid (10P)
– 132 –
4
9
5

Advertisement

Table of Contents
loading